ABNORMAL
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-57
Page
6
Code
03 REVISION 40
AOM-145/1114
CLEAR ICE DETECTED
(APPLICABLE TO EMB-145XR MODEL)
EICAS CAUTION: CLR ICE 1 (2)
LIGHT: CLR ICE 1(2)
LIGHT: Master Caution
Do not takeoff.
Airplane de-icing is required.
If there is no clear ice on the wing surface, disregard the message.
CLEAR ICE DETECTION SYSTEM FAILURE
(APPLICABLE TO EMB-145XR MODEL)
EICAS CAUTION: CLR/I INOP 1 (2)
LIGHT: Master Caution
Check physically if wing surface is free of clear ice before each flight.
If clear ice is found, de-ice the airplane.
WINDSHIELD HEATING FAILURE
EICAS CAUTION: W/S 1 (2) HEAT FAIL
LIGHT: Master Caution
Associated Windshield Heating .................................... OFF