23.04.2012 E-MIG-OS-OS1-MIG0603OSI-E-Manual 1/112
User Manual "Damped Oscillatory Wave Tester "
MIG-OS-OS1
Waveforms: damped oscillatory 100 kHz, 1MHz
MIG0603OSI
Waveforms: damped oscillatory 100 kHz, 1MHz, surge 1.2/50, 8/20 µs, 1.2/50 µs 0.5 J
MIG-OS-OS1 4UH and MIG0603OSI 8 UH
Title: MIG - Modular Impulse Generator
Date: 16.05.99
General Manager: M. Lutz
Service Manager: R. Henz
Revised: 18. December 2010
1 MHz, 100 kHz, SURGE 1.2/50, 8/20 µs, 1.2/50 µs 0.5J
MIG - Modular Impulse Generator

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the EMC-PARTNER MIG-OS-OS1 and is the answer not in the manual?

EMC-PARTNER MIG-OS-OS1 Specifications

General IconGeneral
BrandEMC-PARTNER
ModelMIG-OS-OS1
CategoryPulse Generator
LanguageEnglish

Summary

User Manual Damped Oscillatory Wave Tester

MIG-OS-OS1 Overview

Overview of the MIG-OS-OS1 tester.

MIG0603OSI Overview

Overview of the MIG0603OSI tester.

Attention and Warnings

Important operational notes and warnings.

Declaration of Conformity

States conformity to product standards and directives.

Description of MIG Testers

Applications of the MIG0603-Oxx

Details the function and application of the damped oscillatory wave tester.

CWG Combination Wave Generator

Explains the Combination Wave Generator (CWG) and its applications.

Voltage Tests with 1.2/50 µs 0.5 J

Describes voltage tests using 1.2/50 µs waveform and 0.5 J energy.

Combined and Special MIG Testers

Overview of combined and special MIG testers.

MIG Generator Range

Overview of the MIG generator's capabilities and models.

MIG for Capacitor and CWG Tests

Explains MIG tester use for capacitor tests and CWG.

Technical Specifications

Damped Oscillatory Wave 1 MHz/100 kHz

Technical specifications for 1 MHz and 100 kHz damped oscillatory waves.

Combination Wave Generator Data

Technical data for the Combination Wave Generator (1.2/50 µs; 8/20 µs).

Voltage Tester 1.2/50 µs, 0.5 J, 500 Ω

Technical data for voltage tests with 1.2/50 µs, 0.5 J, and 500 Ω.

MIG Control Information

General control information for MIG testers.

Auxiliary Port and Pin Numbers

Details the auxiliary port and its pin assignments.

Mechanical and Power Specifications

Mechanical Dimensions

Mechanical dimensions for MIGxxxxOSx testers and accessories.

Power Supply Inputs

Information on power supply requirements and connections.

Included Accessories and Dimensions

Lists included articles and their dimensions for MIG testers.

Standard Accessories

Lists standard accessories for MIG testers.

Safety Precautions

Safety Standards Compliance

Outlines the safety standards the MIG0603-Oxx complies with.

Climatic Conditions for Operation

Specifies the operating temperature, humidity, and pressure requirements.

Precautionary Measures During Use

Provides essential safety rules for using the high-voltage generators.

Electromagnetic Compatibility (EMC)

Details EMC immunity requirements and potential disturbances.

Manual as Integral Part

States the manual's importance for safety and operation.

Mechanical Structure and Components

General Mechanical Structure

Provides a general overview of the MIG generator's flexible kit system.

EMC PARTNER High Voltage Module

Describes the high voltage modules forming the basis of MIG generators.

Measuring Circuits for CWG

Explains the measuring circuits used for CWG functions.

Control Panel Operations

Front Panel Overview

Details the important elements on the front panel of the MIG0603-Oxx.

Control Panel Elements

Explains the microprocessor-controlled aspects of the MIG0603-Oxx control panel.

Front Panel Buttons and Functions

Describes the functions of various buttons on the front panel.

Operation Panel Controls

Details controls on the operation panel, including start, stop, and safety circuits.

Rear Panel Layout

Details the rear panel layout and connectors of the MIG0603-Oxx.

Rear Panel Interfaces and Ports

Describes rear panel ports for power, communication, and accessories.

EUT Failed Input and Trigger Input

Explains inputs for EUT failure detection and external triggering.

Preparation for Operation

Manual Reference and Operator Requirements

Emphasizes manual importance and specifies operator qualifications.

Pre-Operation Checks

Outlines pre-operation checks for the tester.

Power Source and Connection

Details power source checks and connection procedures.

Test Setup Guidance

Setup for Combination Wave Pulses

Guides on setting up tests for 1.2/50 µs and 8/20 µs combination wave pulses.

Setup for Damped Oscillatory Waves

Details considerations for setting up damped oscillatory wave tests.

Setup for 0.5 J, 500 Ω Tests

Provides guidance for setting up 0.5 J and 500 Ω tests.

Testing Procedures

Quickstart Guide for MIG0603-Oxx

Guides on performing quick start tests with the MIG0603-Oxx.

Language Selection

Explains how to change the tester's display language.

Protocol and Beeper Settings

Details options for printer output and beeper settings.

Damped Oscillatory Wave Test Procedure

Describes how to perform damped oscillatory wave tests.

Combination Wave Test Procedure

Explains how to perform combination wave tests.

0.5J, 500 Ohm Test Procedure

Guides on performing tests with the 0.5J, 500 Ohm setting.

Function and Setup Descriptions

Programmable Test Overview

Overview of programmable tests for damped oscillatory testers.

Setting Nominal Values - Main Menu

Details how to set nominal values in the "Main" menu.

Damped Oscillatory Wave 1 MHz Test Setup

Setting nominal values for 1 MHz Damped Oscillatory Wave tests.

Damped Oscillatory Wave 100 kHz Test Setup

Setting nominal values for 100 kHz Damped Oscillatory Wave tests.

Editing 0.5 J, 500 Ω Test Parameters

Editing parameters for 0.5 J, 500 Ω tests.

Editing Combination Wave Test Parameters

Editing parameters for Combination Wave Tests.

Ramp Functions for Voltage

Describes voltage ramp functions for SURGE and 1.2/50 0.5 J tests.

Ramp Functions for Polarity

Details ramp functions for polarity changes.

Synchronisation Ramp Functions with CDN

Explains synchronisation ramp functions with external CDN.

EUT Error Control

Describes how EUT errors are controlled and initiated.

High Voltage Operation

Starting and Stopping High Voltage

Guides on starting, stopping, and standby modes for high voltage tests.

Safety Circuit Functionality

Explains the purpose and function of the safety circuit.

EUT Connection Procedures

Provides connection details for EUT for various test types.

Maintenance and Verification

Routine Maintenance Tasks

Instructions for routine maintenance, including cleaning the air filter.

User Verification Procedures

Procedures for user verification of high voltage pulse generation.

Combination Wave Tester Verification

Verification steps for the Combination Wave Tester.

Damped Oscillatory Wave Tester Verification

Verification steps for the Damped Oscillatory Wave tester.

Verification by EMC PARTNER

Information on verification performed by EMC PARTNER before delivery.

Troubleshooting Failed Operations

Errors from Incorrect Inputs

Lists and explains error messages related to incorrect inputs.

Generator Malfunction Messages

Lists and explains failure messages indicating generator malfunction.

Generator Stopped Warnings

Describes attention notices for generator stop conditions.

Service, Parts, and Disposal

Service and Repair Information

Information on service and repair procedures.

Spare Parts Availability

States that no spare parts are necessary.

EMC PARTNER Service Department

Contact details for the EMC PARTNER service department.

Putting the Tester Out of Operation

Instructions for taking the MIG0603-Oxx out of operation.

Recycling and Disposal Information

States that dismantling the MIG0603-Oxx is safe and lists recyclable parts.

Packaging and Transport Procedures

Packaging Instructions

Instructions for packaging the MIG0603-Oxx for transport.

Transport Recommendations

Recommendations for transporting the MIG0603-Oxx, including for outdoor tests.

Accessories for MIG Testers

Accessories for MIGxxxOxx System

Lists accessories for the MIGxxxOxx system.

Accessories for MIG-OS-OS/MIG0603OSI

Lists accessories for MIG-OS-OS and MIG0603OSI testers.

Serial Remote Control

General Remote Control Information

Introduces the remote control option via RS-232 serial port.

RS 232C Serial Port Technical Data

Details the technical specifications of the RS 232C serial port.

Remote Control Command Organization

Explains the structure of remote control commands.

Command Syntax Rules

Defines the syntax rules for remote control commands.

Setup Command Structure

Outlines the structure of setup commands.

Inquire Commands for Data Retrieval

Explains how to inquire for generator data.

Failure Messages in Remote Control

Lists and explains failure messages encountered during remote control.

Remote Control Command Set Reference

Lists and explains various remote control commands.

Overview of MIG Remote Control Commands

GENECS Software for Remote Control

GENECS Software Setup

Instructions for setting up the GENECS software.

GENECS Windows Interface

Describes the GENECS software interface.

GENECS Library for Test Specifications

Explains the GENECS library for test specifications.

GENECS Protocol Capabilities

Details protocol options within GENECS for test reports.

GENECS Log File Functionality

Explains the function of the GENECS log file.

GENECS Preferences Configuration

Describes GENECS software preferences for editors and display.

Appendix and Corrections

Appendix: Waveform Definitions

Defines waveform combinations and specific waveforms.

Corrections and Declarations of Conformity

Information regarding corrections and conformity declarations.

Glossary of Technical Terms

Document Index