Appleton • 1.800.621.1506 • www.appletonelec.com DOC000097A000 Rev. 01 01/11/21 MY7287 • Page 1 of 3
DOC000097A000 INSTRUCTION SHEET
Installation and Maintenance Instructions for Appleton™ Temporary
LED Worksite Lighting
IMPORTANT: RETAIN THIS INSTRUCTION SHEET FOR FUTURE REFERENCE. For safe installation and operation, please read
these instructions carefully and with full understanding.
Product Safety
Signal Words Defined
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous
situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury. NOTICE is used to address practices not related to physical injury.
Safety Instructions
WARNING:
DO NOT OPEN FIXTURE WHILE IT IS ENERGIZED.
DO NOT USE FIXTURE ON UN-GROUNDED CIRCUITS. Failure to ground this luminaire can result in an electrical
shock which may be fatal.
CAUTION:
ELECTRIC SHOCK HAZARD: Disconnect from power (unplug) before servicing.
ELECTRIC SHOCK HAZARD: DISCONNECT luminaire from power source before inspection or repair work
is attempted.
Failure of the luminaire to operate could result from a break in the power circuit or failure of a component. In this
case, the luminaire is not operational, DO NOT operate.
Take note of caution labels on product.
Inspect cord regularly for damage.
Do not submerge any part of product in liquids.
Do not hang xture by its electrical cord. Make sure to use the manufacturer’s handle or hanging hole located at
the top of the unit..
Take care not to drop xture, as damage to the product may result.
Do not connect other loads such as appliances, space heaters or power tools to the light string.
NOTICE:
Please read this manual carefully before initial use to make sure the application is in accordance with all
instructions.
To reduce the risk of electric shock and re, do not exceed string maximum wattage including any additional
string loads. Maximum number of connected luminaires: 100W – 6 units.
Luminaires are suitable for dry and damp locations, however, make sure to never submerge any part of the xture
in liquids of any kind.
Disconnect the power to avoid shock when the equipment is wet.
This device is not intended for use with emergency exits.
The product should not be installed in extreme heat, sealed environments, or areas with corrosive gases, so as
not to affect the service life.
This luminaire must be installed, tested and maintained by professionals familiar with all national and local
electrical codes.
Please inspect the product carefully after opening the package. If damaged, please keep the packaging and
immediately contact your local supplier.
Question and Answer IconNeed help?

Do you have a question about the Emerson Appleton and is the answer not in the manual?

Summary

Product Safety

Signal Words Defined

Defines DANGER, WARNING, CAUTION, and NOTICE signal words used to indicate hazard levels and practices.

Safety Instructions

Provides critical safety warnings and precautions for installation, operation, and maintenance of the luminaire.

Operating Instructions

Mounting the Luminaire

Instructions for securely attaching the portable electric luminaire to a ceiling or wall using its handle or hanging hole.

Connecting Multiple Units

Guidance on linking additional luminaires in series, including plug connection and buckle securing for 100W units.

Power Source Connection

Details on locating and connecting the luminaire to a 120V AC 50/60Hz power source using a grounded outlet.

Troubleshooting

Electrical Troubleshooting

Steps to verify supply voltage and check for shorts to ground using a Digital Multimeter (DMM).

Maintenance and Inspection

Guidance on inspecting for cracks on the luminaire and checking the power cord for damage before use.

Summary

Product Safety

Signal Words Defined

Defines DANGER, WARNING, CAUTION, and NOTICE signal words used to indicate hazard levels and practices.

Safety Instructions

Provides critical safety warnings and precautions for installation, operation, and maintenance of the luminaire.

Operating Instructions

Mounting the Luminaire

Instructions for securely attaching the portable electric luminaire to a ceiling or wall using its handle or hanging hole.

Connecting Multiple Units

Guidance on linking additional luminaires in series, including plug connection and buckle securing for 100W units.

Power Source Connection

Details on locating and connecting the luminaire to a 120V AC 50/60Hz power source using a grounded outlet.

Troubleshooting

Electrical Troubleshooting

Steps to verify supply voltage and check for shorts to ground using a Digital Multimeter (DMM).

Maintenance and Inspection

Guidance on inspecting for cracks on the luminaire and checking the power cord for damage before use.

Overview

The provided document describes the Appleton™ Temporary LED Worksite Lighting, a portable electric luminaire designed for temporary illumination in worksite environments.

Function Description

The Appleton™ Temporary LED Worksite Lighting is designed to provide temporary illumination in various worksite settings. It is a portable electric luminaire that can be secured to ceilings or walls using a handle or hanging hole located at the top of the unit. Multiple units can be linked together in series to extend the illuminated area. The device is intended for use by industrial users and professionals familiar with electrical codes and equipment maintenance.

Important Technical Specifications

  • Power Rating: Rated for 120V AC 50/60Hz.
  • Weight: Each luminaire unit weighs 4.2 lb.
  • Maximum Connected Units: Up to six 100W units can be connected in series.
  • Maximum String Wattage: The total string wattage, including any additional string loads, must not exceed the specified maximum (e.g., for 100W units, 6 units max).
  • Environmental Suitability: Suitable for dry and damp locations. Not intended for use in extreme heat, sealed environments, or areas with corrosive gases, as these conditions may affect service life.
  • Grounding: Requires use on grounded circuits to prevent electrical shock.
  • Emergency Exits: Not intended for use with emergency exits.

Usage Features

  • Portability and Mounting: The luminaire is portable and can be easily secured to ceilings or walls using its integrated handle or hanging hole. Users must ensure the attachment means can support the unit's weight (4.2 lb).
  • Daisy-Chaining Capability: Multiple units can be linked in series. This is achieved by opening a receptacle access door on one luminaire and connecting the plug of an additional luminaire into the receptacle. A buckle then rotates downward to secure the molded plug end.
  • Receptacle Access Door: The receptacle access door should be kept closed if luminaires are not connected in series to maintain safety and integrity.
  • Power Source Connection: The luminaire connects to a 120V AC 50/60Hz power source. It is crucial to always use a grounded outlet.
  • Disconnection: To discontinue use, the power cord must be disconnected from the power source.
  • Load Restrictions: Users are explicitly warned not to connect other loads such as appliances, space heaters, or power tools to the light string, as this can exceed the maximum string wattage and pose a risk of electric shock and fire.
  • Environmental Considerations: While suitable for damp locations, the product should never be submerged in liquids. Care should be taken not to drop the fixture to prevent damage.
  • Installation Guidance: Installation, testing, and maintenance must be performed by professionals familiar with all national and local electrical codes.

Maintenance Features

  • Pre-Use Inspection: Upon opening the package, the product should be carefully inspected for any damage. If damaged, the packaging should be retained, and the local supplier contacted immediately.
  • Regular Cord Inspection: The electrical cord should be regularly inspected for any signs of damage. If the power cord shows damage or punctures, the luminaire should not be used, and a new one should be purchased.
  • Fixture Integrity Check: Periodically check the diffuser and the top or bottom body of the luminaire for cracks or damage. Any cracks or damage necessitate ordering a replacement luminaire.
  • Troubleshooting Electrical Issues:
    • Voltage Verification: If the luminaire fails to operate, a Digital Multimeter (DMM) set to the volt AC scale can be used to verify that the supply voltage is correct (120±5VAC).
    • Ground Short Check: A DMM set to its lowest Ohm scale can be used to check for a short to ground. This involves firmly touching one lead to a plug blade and the other to the ground pin. An open circuit reading (infinite Ohms) should be observed. If a short exists, the luminaire must not be operated.
  • Power Disconnection for Servicing: Before attempting any inspection or repair work, the luminaire must be disconnected (unplugged) from its power source to prevent electric shock.
  • Non-Operational Status: If the luminaire fails to operate due to a break in the power circuit or a component failure, it is considered non-operational and should not be operated.
  • Caution Label Awareness: Users should take note of all caution labels present on the product.
  • Proper Handling: The fixture should not be hung by its electrical cord; instead, the manufacturer's handle or hanging hole at the top of the unit should be used.
  • Liquid Contact: The product should not be submerged in liquids. If the equipment becomes wet, the power should be disconnected to avoid shock.
  • Load Restrictions (Maintenance Context): Do not connect other loads such as appliances, space heaters, or power tools to the light string.
  • Packaging Retention: In case of damage upon delivery, keep the packaging and contact the supplier.
  • Documentation: Retain the instruction sheet for future reference to ensure safe installation and operation.

Emerson Appleton Specifications

General IconGeneral
BrandEmerson
ModelAppleton
CategoryWork Light
LanguageEnglish