Summary

Chapter 1: Introduction

1.1 VersaMax PROFINET Scanner Overview

Provides a high-level understanding of the PNS module's function and role in PROFINET networks.

1.2 VersaMax PROFINET Scanner Versions

Details the two available hardware versions of the PNS module, specifying media types.

1.3 VersaMax PROFINET Scanner Specifications

Lists the technical capabilities and physical attributes of the PNS module.

1.3.1 VersaMax PROFINET Scanner LEDs

Explains the function and status indication of each LED on the PNS module.

1.3.2 Power Supply Modules

Describes the types and installation of power supply modules compatible with the PNS.

1.3.3 Ethernet Network Ports

Details the specifications and connection types of the Ethernet ports on the PNS.

1.3.4 USB Port

Provides information on the USB port's purpose, primarily for firmware updates.

1.4 Compatible VersaMax Modules, Carriers, and Power Supplies

Lists modules, carriers, and power supplies that can be used with the PNS.

Chapter 2: Installation

2.1 Module Installation

Covers the physical mounting of the PNS module onto a DIN rail or panel.

2.1.1 Cable and Connector Clearance Requirements

Specifies necessary space for cables and connectors for proper installation and reliability.

2.2 General Installation Requirements

Outlines essential installation practices, including safety and environmental considerations.

2.2.1 Installation in Hazardous Areas

Provides specific guidelines for installing the module in hazardous locations per UL and ATEX standards.

2.2.2 ATEX Marking

Explains the meaning of ATEX markings related to explosive atmospheres.

2.2.3 Installing the Module on a DIN Rail

Details the process of mounting the module onto a standard DIN rail.

2.2.4 Removing the Module from the DIN Rail

Describes how to safely detach the module from the DIN rail.

2.2.5 Installing Power Supplies

Guides through the process of connecting and securing power supply modules to the PNS.

2.3 PROFINET Scanner Power-up and Restart

Explains the sequence of events during module power-up and how to restart it.

2.4 LED Operation

Describes the meaning of the status and activity LEDs on the PNS module.

2.4.1 Special LED Blink Patterns

Details specific LED blink sequences that indicate special conditions or errors.

2.5 Firmware Updates

Covers the procedures for updating the firmware of the PNS module.

2.5.1 Firmware Update for Modules in the Remote Node

Explains how to update firmware for modules connected to the PNS.

Installing the USB Port Driver

Guides on installing the necessary driver for USB firmware updates.

Chapter 3: Configuration

3.1 Configuration Overview

Introduces the overall process of configuring the PNS and its associated I/O devices.

3.1.1 Basic Configuration Steps

Outlines the fundamental steps required to configure the PROFINET system.

3.1.2 Configuration Tool

Specifies the requirements for the PROFINET IO configuration tool.

3.2 Adding a VersaMax PROFINET Scanner to a LAN

Details the process of integrating the PNS into a PROFINET network.

3.2.1 Configuring VersaMax PROFINET Scanner Parameters

Explains how to set up the core parameters for the PNS module.

3.2.1.1 Media Redundancy Parameters

Covers the configuration settings for Media Redundancy Protocol (MRP).

3.2.1.2 Hot-Standby CPU Redundancy using PROFINET I;O Parameters

Describes configuration for HSB CPU redundancy with PROFINET I/O.

3.2.2 Adding VersaMax PROFINET Scanner Power Supplies

Explains how to configure power supplies for the PNS in the setup tool.

3.2.3 Adding VersaMax Modules to a Remote Node

Details how to add various VersaMax modules to the remote node configuration.

3.2.4 Adding Power Supplies between Modules

Discusses the installation of additional power supplies between modules.

3.2.5 Configuring VersaMax Module Parameters

Covers the configuration of parameters for individual VersaMax modules.

3.2.6 Configuring Analog Modules that Have Jumpers

Guides on configuring analog modules that require specific jumper settings.

3.3 Assigning IO-Device Names

Explains the process of assigning unique names to IO-Devices using DCP.

3.4 After the Configuration is Stored to the IO-Controller

Describes the behavior and data transfer after configuration is saved to the IO-Controller.

3.5 Output Operation

Details how module outputs behave during configuration and operation phases.

3.6 Clearing the IO-Controller Configuration

Outlines the reaction of the PNS to clearing the IO-Controller's configuration.

3.7 Replacing PROFINET Scanner Hardware

Provides step-by-step instructions for replacing the PNS module.

Chapter 4: Diagnostics

4.1 PROFINET Scanner Status and Control Data

Explains how to monitor scanner status and use control bits for diagnostics.

4.1.1 Output Control Bits

Details the specific output bits used to trigger diagnostic actions and clear faults.

4.1.2 Input Status Bits

Describes the input status bits that provide information about the scanner's health and connectivity.

4.2 Error Handling

Covers the methods for handling fatal errors and PROFINET diagnostic alarms.

4.2.1 Fatal Error Handling

Explains how the system manages fatal errors, including blinking codes and automatic restarts.

4.2.2 PROFINET Alarms

Describes how the PNS reports non-fatal errors and diagnostic information to the controller.

4.2.3 Clearing Faults on VersaMax Analog Modules

Provides procedures for clearing faults specifically on VersaMax analog modules.

4.2.4 PROFINET Module Loss, Add & Mismatch Faults

Details how the PNS detects and reports issues with module presence or configuration.

4.3 Diagnostics for BEM003 PROFIBUS DP Networks

Specific diagnostic information related to the BEM003 PROFIBUS DP Master module.

Chapter 5: Maintenance Mode

5.1 Entering Maintenance Mode and Performing Maintenance

Step-by-step guide to activate and use Maintenance Mode for servicing.

5.2 Exiting Maintenance Mode and Restoring Operation

Instructions on how to safely return the PNS from Maintenance Mode to Normal Mode.

5.3 Maintenance Mode Retentiveness through Power Cycle

Explains how the module's mode is preserved across power interruptions.

Appendix A: PROFINET Specifications

A.1 PROFINET Protocol Support

Lists the various PROFINET protocols and features supported by the PNS.

A.2 Technical Data

Provides essential technical specifications and performance data for the PNS.

A.3 Limitations

Highlights features that are not supported in the current release of the PNS.

Summary

Chapter 1: Introduction

1.1 VersaMax PROFINET Scanner Overview

Provides a high-level understanding of the PNS module's function and role in PROFINET networks.

1.2 VersaMax PROFINET Scanner Versions

Details the two available hardware versions of the PNS module, specifying media types.

1.3 VersaMax PROFINET Scanner Specifications

Lists the technical capabilities and physical attributes of the PNS module.

1.3.1 VersaMax PROFINET Scanner LEDs

Explains the function and status indication of each LED on the PNS module.

1.3.2 Power Supply Modules

Describes the types and installation of power supply modules compatible with the PNS.

1.3.3 Ethernet Network Ports

Details the specifications and connection types of the Ethernet ports on the PNS.

1.3.4 USB Port

Provides information on the USB port's purpose, primarily for firmware updates.

1.4 Compatible VersaMax Modules, Carriers, and Power Supplies

Lists modules, carriers, and power supplies that can be used with the PNS.

Chapter 2: Installation

2.1 Module Installation

Covers the physical mounting of the PNS module onto a DIN rail or panel.

2.1.1 Cable and Connector Clearance Requirements

Specifies necessary space for cables and connectors for proper installation and reliability.

2.2 General Installation Requirements

Outlines essential installation practices, including safety and environmental considerations.

2.2.1 Installation in Hazardous Areas

Provides specific guidelines for installing the module in hazardous locations per UL and ATEX standards.

2.2.2 ATEX Marking

Explains the meaning of ATEX markings related to explosive atmospheres.

2.2.3 Installing the Module on a DIN Rail

Details the process of mounting the module onto a standard DIN rail.

2.2.4 Removing the Module from the DIN Rail

Describes how to safely detach the module from the DIN rail.

2.2.5 Installing Power Supplies

Guides through the process of connecting and securing power supply modules to the PNS.

2.3 PROFINET Scanner Power-up and Restart

Explains the sequence of events during module power-up and how to restart it.

2.4 LED Operation

Describes the meaning of the status and activity LEDs on the PNS module.

2.4.1 Special LED Blink Patterns

Details specific LED blink sequences that indicate special conditions or errors.

2.5 Firmware Updates

Covers the procedures for updating the firmware of the PNS module.

2.5.1 Firmware Update for Modules in the Remote Node

Explains how to update firmware for modules connected to the PNS.

Installing the USB Port Driver

Guides on installing the necessary driver for USB firmware updates.

Chapter 3: Configuration

3.1 Configuration Overview

Introduces the overall process of configuring the PNS and its associated I/O devices.

3.1.1 Basic Configuration Steps

Outlines the fundamental steps required to configure the PROFINET system.

3.1.2 Configuration Tool

Specifies the requirements for the PROFINET IO configuration tool.

3.2 Adding a VersaMax PROFINET Scanner to a LAN

Details the process of integrating the PNS into a PROFINET network.

3.2.1 Configuring VersaMax PROFINET Scanner Parameters

Explains how to set up the core parameters for the PNS module.

3.2.1.1 Media Redundancy Parameters

Covers the configuration settings for Media Redundancy Protocol (MRP).

3.2.1.2 Hot-Standby CPU Redundancy using PROFINET I;O Parameters

Describes configuration for HSB CPU redundancy with PROFINET I/O.

3.2.2 Adding VersaMax PROFINET Scanner Power Supplies

Explains how to configure power supplies for the PNS in the setup tool.

3.2.3 Adding VersaMax Modules to a Remote Node

Details how to add various VersaMax modules to the remote node configuration.

3.2.4 Adding Power Supplies between Modules

Discusses the installation of additional power supplies between modules.

3.2.5 Configuring VersaMax Module Parameters

Covers the configuration of parameters for individual VersaMax modules.

3.2.6 Configuring Analog Modules that Have Jumpers

Guides on configuring analog modules that require specific jumper settings.

3.3 Assigning IO-Device Names

Explains the process of assigning unique names to IO-Devices using DCP.

3.4 After the Configuration is Stored to the IO-Controller

Describes the behavior and data transfer after configuration is saved to the IO-Controller.

3.5 Output Operation

Details how module outputs behave during configuration and operation phases.

3.6 Clearing the IO-Controller Configuration

Outlines the reaction of the PNS to clearing the IO-Controller's configuration.

3.7 Replacing PROFINET Scanner Hardware

Provides step-by-step instructions for replacing the PNS module.

Chapter 4: Diagnostics

4.1 PROFINET Scanner Status and Control Data

Explains how to monitor scanner status and use control bits for diagnostics.

4.1.1 Output Control Bits

Details the specific output bits used to trigger diagnostic actions and clear faults.

4.1.2 Input Status Bits

Describes the input status bits that provide information about the scanner's health and connectivity.

4.2 Error Handling

Covers the methods for handling fatal errors and PROFINET diagnostic alarms.

4.2.1 Fatal Error Handling

Explains how the system manages fatal errors, including blinking codes and automatic restarts.

4.2.2 PROFINET Alarms

Describes how the PNS reports non-fatal errors and diagnostic information to the controller.

4.2.3 Clearing Faults on VersaMax Analog Modules

Provides procedures for clearing faults specifically on VersaMax analog modules.

4.2.4 PROFINET Module Loss, Add & Mismatch Faults

Details how the PNS detects and reports issues with module presence or configuration.

4.3 Diagnostics for BEM003 PROFIBUS DP Networks

Specific diagnostic information related to the BEM003 PROFIBUS DP Master module.

Chapter 5: Maintenance Mode

5.1 Entering Maintenance Mode and Performing Maintenance

Step-by-step guide to activate and use Maintenance Mode for servicing.

5.2 Exiting Maintenance Mode and Restoring Operation

Instructions on how to safely return the PNS from Maintenance Mode to Normal Mode.

5.3 Maintenance Mode Retentiveness through Power Cycle

Explains how the module's mode is preserved across power interruptions.

Appendix A: PROFINET Specifications

A.1 PROFINET Protocol Support

Lists the various PROFINET protocols and features supported by the PNS.

A.2 Technical Data

Provides essential technical specifications and performance data for the PNS.

A.3 Limitations

Highlights features that are not supported in the current release of the PNS.