21D83M-843
Integrated Single Stage
Furnace Control Replacement Kit
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
PRECAUTIONS
INSTALLATION INSTRUCTIONS
Kit includes:
1 – 50A66-843 ignition control board
1 – Wiring harness (9-pin to 12-pin)
1 – Wiring harness (4-pin to 6-pin)
1 – Mounting panel
4 – Stand-off fasteners
1 – Circuit breaker
1 – 4" blue wire
2 – Wiring diagrams
Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure
proper operation.
WARNING
!
Failure to comply with the following warnings
could result in personal injury or property damage.
FIRE HAZARD
Do not exceed the specified voltage.
Replace existing control with exact model
and dash number.
Protect the control from direct contact with
water (dripping, spraying, rain, etc.).
If the control has been in direct contact with
water, replace the control.
Label all wires before disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Route and secure wiring away from flame.
SHOCK HAZARD
Disconnect electric power before servicing.
Ensure proper earth grounding of appliance.
Ensure proper connection of line neutral and
line hot wires.
EXPLOSION HAZARD
Shut off main gas to appliance until installa-
tion is complete.
CAUTION
!
Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage
the thermostat.
The kit includes the 50A66-843 which is an automatic gas
interrupted ignition control that employs a microprocessor
to continually monitor, analyze, and control the proper
operation of the gas burner, inducer, and fan.
These controls incorporate system fault analysis for quick
gas flow shut-off, coupled with automatic ignition retry
upon sensing a fault correction.
Lennox White-Rodgers Page Reference
10M9301
12L6901
32M8801
56L8401
50A65-120
50A65-121
3 PROCEDURE 1
Figure 1, Picture
1, Table 1, Wiring
Diagram 5001-6973
24L8501
63K8901
97L4801
50A62-120
50A62-121
50A62-820
4 PROCEDURE 2
Figure 1, Picture
2, Table 2, Wiring
Diagram 5001-6972
100925-01
100925-03
17W9201
23W5101
30W2501
69M0801
69M1501
83M00
21D83M-843
50A66-122
50A66-123
5 PROCEDURE 3
The 21D83M-843 kit will replace the following Controls:
Follow instructions for replacement of your model num-
ber under the heading INSTALLATION.
PART NO. 37-7337C
Replaces 37-7337B
1515
white-rodgers.com
emersonclimate.com

Questions and Answers:

Emerson White-Rodgers 21D83M-843 Specifications

General IconGeneral
Voltage24 VAC
BrandEmerson White-Rodgers
Model21D83M-843
Operating Voltage24 VAC
Frequency50/60 Hz
ApplicationFurnace control systems
CategoryFurnace Control
Operating Temperature-40°C to 79°C
Humidity5% to 95% relative humidity (non-condensing)

Summary

Installation Instructions and Safety

General Precautions and Warnings

Crucial safety warnings and cautions for installation and operation to prevent injury or damage.

Specifications and Timing

Electrical Ratings and Operating Parameters

Details electrical ratings, humidity range, mounting, and operating temperature of the control.

Control Timing Specifications

Outlines the timing parameters for various operational events like pre-purge, ignition, and fan delays.

Installation Procedure 1

Replacing Specific Control Models

Step-by-step instructions for replacing Lennox, White-Rodgers, and other specified control models.

Installation Procedure 2

Replacing Additional Control Models

Detailed guide for replacing a wider range of Lennox, White-Rodgers, and other specified control models.

Installation Procedure 3

Configuration and Heat Mode Operation

Instructions for replacing specific models, configuring option switches, and understanding heat mode operation.

System Operation and Status

Operational Modes (Cool, Manual Fan)

Details the control's function in cool mode and manual fan operation.

Lockout and Diagnostic Features

Explains system lockout conditions, reset procedures, and diagnostic LED indicators.

Troubleshooting and Diagnostics

Diagnostic Table and Error Resolution

A table correlating LED status to error conditions and providing troubleshooting advice.