VERTICAL (VCH ) AND HORIZONTAL (HCA/HCH)
IN-WALL STRAIGHT COOL CONDENSING UNITS
P/N 240000664, Rev. 2.1 [06/04]
Nominal Circuits:
VCH
(18,000, 24,000 & 30,000 Btuh)
HCA
(18,000 & 24,000 Btuh)
HCH
(24,000 & 30,000 Btuh)
Enviromaster International LLC
5780 Success Dr.
Rome, NY 13440
Email: emi@enviromaster.com
VCH
HCA
HCH
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
An ISO 9001-2000 Certified Company
Question and Answer IconNeed help?

Do you have a question about the EMI VCH Series and is the answer not in the manual?

EMI VCH Series Specifications

General IconGeneral
BrandEMI
ModelVCH Series
CategoryHeat Pump
LanguageEnglish

Summary

INSTALLER RESPONSIBILITIES

Save Instructions

Instructions for installers to save and refer to for future use.

Report Shipping Damage

Instructions to immediately report any shipping damage to the carrier.

Technical Service and Warranty Assistance

Information on obtaining technical service or warranty assistance for the unit.

WARNINGS

General Unit Operation Warnings

Crucial warnings for safe and proper installation and operation of the condensing unit.

PRE-INSTALLATION

Unpack and Inspect Unit

Procedure for unpacking the unit and inspecting it for damage, including making freight claims.

Inspect Installation Location

Check planned locations for evaporator and condenser, modify wall openings if necessary.

Eliminate Air Recirculation Obstructions

Ensure no outdoor obstructions cause discharge air to recirculate to the intake.

Plan Piping and Wiring Routing

Plan the routing for piping and wiring, ensuring service access is not blocked.

Thermostat Requirements

Use a low voltage wall thermostat and follow manufacturer's installation instructions.

Evaporator Unit Transformer

Ensure a 24V step-down transformer is installed in the evaporator section for control power.

Evaporator Compatibility

Note on matching EMI units with other manufacturers' evaporators for warranty.

INSTALLATION

Install Outdoor Louver

Install the outdoor louver to the chassis if not factory installed.

Position and Secure Unit

Set the unit in the wall opening with a 1/4" pitch to the outside and secure it.

Electrical Wiring Connections

Guidelines for electrical wiring, grounding, and using appropriate conductors and disconnect switches.

Refrigerant Line Installation

Procedure for running interconnecting refrigerant lines, guarding against kinks and noise transmission.

START-UP

Adjust Refrigerant Charge

Start the unit and adjust refrigerant charge using superheat or temperature vs. pressure method.

Replace Panels and Test System

Replace removed panels and test the system for proper operation.

Final Visual Inspection

Conduct a final visual inspection for weather tightness and correct any deficiencies.

TROUBLESHOOTING

Power and Thermostat Check

Check unit power and thermostat satisfaction. Refer to wiring diagram for component checks.

FIELD CHARGING

Superheat Method Recommendation

Recommends the superheat method for field charging for optimal performance.

Superheat Charging Chart Instructions

Instructions on how to use the superheat charging chart to determine and adjust refrigerant charge.

ELECTRICAL SPECIFICATIONS AND DIMENSIONS

Unit Specifications and Diagrams

Provides diagrams of VCH, HCA, HCH units and their electrical specifications.

ALL PRODUCT LIMITED WARRANTY

Warranty Coverage Details

Details what EMI will cover, including part replacement for defects.

Exclusions from Warranty

Lists items not covered by the warranty, such as labor and consequential damages.

Limitations of Warranties

States the warranty is exclusive and in lieu of implied warranties.

Service or Repair Contact

Information on how to contact for service or repair, including installer and factory contact.