EZM-4430 48x48 DIN 1/16 Programmable Counter
EZM-4430 48 x 48 DIN 1/16
Universal Input Programmable Counter
Introduction Manual. ENG EZM-4430 02 V03 08/14
-
-
-
6 digits Process (PV) and 6 digits Set (SV) Value Display
- Operation with 1 Set Value
- Reset , Pause and ChA-ChB Counting Inputs
Operation with Automatic and Manual Reset
NPN/PNP Type Operation
- INC , DEC , INC / INC , INC / DEC , UP / DOWN , x1 / x2 / x4
Counting with Phase Shifting Property in Counter Function
- Multiplication Coefficient and Decimal Point Position

Other manuals for EMKO EZM-4430

Question and Answer IconNeed help?

Do you have a question about the EMKO EZM-4430 and is the answer not in the manual?

EMKO EZM-4430 Specifications

General IconGeneral
BrandEMKO
ModelEZM-4430
CategoryCash Counter
LanguageEnglish

Summary

1. Preface

1.1 General Specifications

Details the technical specifications and features of the EZM-4430 counter.

1.2 Ordering Information

Provides details on how to order the EZM-4430 counter with various configurations.

1.3 Warranty

Outlines the warranty period and conditions for the EMKO EZM-4430 counter.

1.4 Maintenance

Offers guidelines for cleaning and basic upkeep of the EZM-4430 programmable counter.

2. Installation

2.1 General Description

Provides an overview of the EZM-4430 counter's front panel, device label, and mounting clamps.

2.2 Dimensions

Details the physical dimensions and panel cut-out requirements for the EZM-4430 counter.

2.3 Panel Cut-out

Specifies the required dimensions for the panel opening to mount the EZM-4430 counter.

2.4 Environmental Ratings

Lists the operating conditions, forbidden conditions, and altitude limits for the EZM-4430 counter.

2.5 Panel Mounting

Explains the step-by-step procedure for mounting the EZM-4430 counter onto a control panel.

2.6 Installation Fixing Clamp

Details how to use the fixing clamps for secure panel mounting of the EZM-4430 counter.

2.7 Removing from the Panel

Provides instructions on how to safely remove the EZM-4430 counter from its panel mount.

3. Electrical Wirings

3.1 Terminal Layout and Connection Instructions

Illustrates the terminal layout and provides instructions for making electrical connections to the EZM-4430.

3.2 Electrical Wiring Diagram

Presents the detailed wiring diagram for connecting sensors, inputs, outputs, and power to the EZM-4430.

3.3 View of Device Label

Shows the labeling on the EZM-4430 device, indicating terminal functions and specifications.

3.4 Connection of Device Supply Voltage Input

Explains how to connect the power supply voltage to the EZM-4430 counter, including fuse and switch requirements.

3.5 Counting Input Connection

Details how to connect various counting inputs like proximity sensors and switches to the EZM-4430.

3.5.1 Proximity & Switch Connection

Illustrates wiring for NPN and PNP proximity sensors and simple switches for counting inputs.

3.5.2 Incremental Encoder & Switch Connection

Shows how to connect incremental encoders and switches for counting inputs to the EZM-4430.

3.5.3 Switch Connection

Provides wiring diagrams for connecting simple switches to the counting inputs of the EZM-4430.

3.6 Relay Output Wiring Diagram

Illustrates the wiring diagram for the relay output of the EZM-4430 counter.

3.7 Galvanic Isolation Test Results

Presents the galvanic isolation test results for the EZM-4430 programmable counter.

4. Definition of Front Panel and Accessing to the Set Parameters

4.1 Definition of Front Panel

Details the functions of the buttons, displays, and LED indicators on the EZM-4430's front panel.

4.2 Power On Observation and Software Revision

Describes what is displayed on the EZM-4430 screen when power is applied, including software revision.

4.3 Adjustment of SET Value

Provides a step-by-step guide on how to change and save the Set Value (SV) on the EZM-4430 counter.

4.4 Resetting the Count Value

Explains how to reset the count value using the RESET button or input, and the effect on actual and SET values.

4.5 Accessing to the Program Parameters

Details the process of accessing and navigating through the EZM-4430's program parameters, including password entry.

5. Program Parameters

Input Types and Functions

Defines the various input types and functional behaviors available for the EZM-4430 counter.

x1 Phase Shifting for Incremental Encoders

Explains x1 phase shifting for incremental encoders, defining counting based on Ch-A and Ch-B signals.

x2 Phase Shifting for Incremental Encoders

Details x2 phase shifting for incremental encoders, covering various counting scenarios with Ch-A and Ch-B.

x4 Phase Shifting for Incremental Encoders

Describes x4 phase shifting for incremental encoders, outlining complex counting logic with Ch-A and Ch-B.

Filter Time for Ch-A and Ch-B Inputs

Sets protective pulse time for Ch-A and Ch-B inputs against debounce and weak signals.

Filter Time for Reset and Pause Inputs

Sets protective pulse time for reset and pause inputs against debounce and weak signals.

Direction of Counting

Configures the counting direction (upcount or downcount) for the EZM-4430 counter.

Sensor Type Selection

Selects the sensor type (NPN or PNP) for the counting inputs of the EZM-4430.

Output Functions: Manual Reset-1

Defines 'Manual Reset-1' output behavior, where counting continues until manual reset.

Output Functions: Manual Reset-2

Defines 'Manual Reset-2' output behavior, where counting stops at SET value until manual reset.

Output Functions: Manual Reset-3

Details 'Manual Reset-3' output behavior, considering output pulse time for state changes.

Output Functions: Automatic Reset-1

Explains 'Automatic Reset-1' behavior, where count resets automatically after reaching SET value.

Output Functions: Automatic Reset-2

Details 'Automatic Reset-2' behavior, including reset and counting start points based on pulse time.

Output Functions: Automatic Reset-3

Describes 'Automatic Reset-3' behavior, where output changes at SET value, with specific conditions for pulse time.

Output Functions: Automatic Reset-4

Explains 'Automatic Reset-4' behavior, where output changes at SET value and counting resets.

Output Functions: Automatic Reset-5

Details 'Automatic Reset-5' behavior, where output state depends on count value relative to SET value.

Output Functions: Automatic Reset-6

Describes 'Automatic Reset-6' behavior, with output changes at 0 value and conditions for count value.

Output Functions: Automatic Reset-7

Explains 'Automatic Reset-7' behavior, where output state depends on count value relative to SET value or zero.

Output Run Type

Configures whether the output is normally non-energized or energized during operation.

Output Pulse Time

Sets the duration for which the output signal remains active after a counting event.

Point Position for Display

Specifies the decimal point position for the display of values on the EZM-4430 counter.

Data Record

Defines how count values are saved to memory upon power disconnection and restoration.

Reset and Set Protection

Configures protection levels for the reset function and the ability to change the set value.

Multiplication Coefficient

Sets a multiplier to scale the counted pulses, affecting the displayed value.

Reset Offset

Determines the value to which the counter resets after a reset operation.

Program Password

Sets or changes the password required to access the program parameters of the counter.

6. Failure Messages

7. Specifications

8. Other Informations