EasyManua.ls Logo

Empire Comfort Systems VFD36FB0L-1 - User Manual

Empire Comfort Systems VFD36FB0L-1
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
UNIVERSAL FIREBOX FOR
ALL VENT-FREE LOG SETS
MODELS
VFD32FB0L-1 VFD36FB0L-1 VFD42FB0L-1
VFD32FB2DL-1 VFD36FB2DL-1 VFD42FB2DL-1
VFD32FB2CL-1 VFD36FB2CL-1 VFD42FB2CL-1
VFD32FB2ML-3 VFD36FB2ML-3 VFD42FB2ML-3
VFD32FB0F-1 VFD36FB0F-1 VFD42FB0F-1
VFD32FB2DF-1 VFD36FB2DF-1 VFD42FB2DF-1
VFD32FB2CF-1 VFD36FB2CF-1 VFD42FB2CF-1
VFD32FB2MF-3 VFD36FB2MF-3 VFD42FB2MF-3
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
The Breckenridge
Deluxe Vent-Free Universal Fireboxes
DO NOT ATTEMPT TO MODIFY OR ALTER THE
CONSTRUCTION OF THE FIREBOX OR ITS COMPO-
NENTS. ANY MODIFICATION OR ALTERATION OF
CONSTRUCTION MAY VOID THE WARRANTY OF
THIS FIREBOX.
CHILDREN AND ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE TEMPERATURE
AND SHOULD STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SU-
PERVISED WHEN THEY ARE IN THE SAME ROOM
AS THE FIREBOX.
ANSI Z21.91 Ventless Fireplace Enclosures for Gas Fired
Decorative Type Unvented Room Heaters
— Donotstoreorusegasolineorotherammablevapors
and liquids in the vicinity of this or any other appli-
ance.
WHAT TO DO IF YOU SMELL GAS
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch;donotuseany
phoneinyourbuilding.
• Immediatelycallyourgassupplierfromaneigh-
bor’s phone. Follow the gas suppliers instruc-
tions.
• Ifyoucannotreachyourgassupplier,callthere
department.
— Installationandservicemustbeperformedbyaquali-
edinstaller,serviceagencyorthegassupplier.
WARNING: If the information in these instructions are
notfollowedexactly,areorexplosionmayresultcaus-
ingpropertydamage,personalinjuryorlossoflife.
Carefullyreviewtheinstructionssuppliedwiththedecorative
typeunventedroomheaterfortheminimumreplacesize
requirement.
DO NOT INSTALL A VENT-FREE LOG SET IN THIS
FIREBOX, UNLESS THIS FIREBOX MEETS THE
MINIMUM DIMENSIONS REQUIRED FOR THE
INSTALLATION.
WARNING:Improperinstallation,adjustment,alteration,
serviceormaintenancecancauseinjuryorpropertydamage.
Refer to this manual. For assistance or additional informa-
tion,consultaqualiedinstaller,serviceagencyorthegas
supplier.
FOR USE ONLY WITH A LISTED GAS-FIRED
UNVENTED DECORATIVE ROOM HEATER NOT TO
EXCEED40,000BTU/H.
DO NOT BUILD A WOOD FIRE.
Installer: Leavethismanualwiththeappliance.
Consumer: Retain this manual for future reference.
GAS-FIRED
Question and Answer IconNeed help?

Do you have a question about the Empire Comfort Systems VFD36FB0L-1 and is the answer not in the manual?

Summary

Introduction

Instructions to Installer

Installer must leave instruction manual with owner after installation.

Qualified Installing Agency

Installation/replacement of gas piping, equipment, or accessories, and repair/servicing shall be performed only by a qualified agency.

State of Massachusetts:

The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Clearances

Sidewall Clearances

The clearance from the inside of the firebox to perpendicular combustible side wall should not be less than 6".

Firebox Side and Back Clearances

The firebox outer casing side and back flanges are zero clearance to combustibles.

Top Framing and Finishing

Combustible framing may rest on standoffs. Finishing materials may extend to top standoff screws on front edge of outer wrap.

Firebox Installation Instructions

Planning Your Installation

Note that the optional BVA1 Fresh Air kit must be installed at the time of the initial installation.

Firebox Framing

Firebox framing can be built before or after setting the firebox. Position framing to accommodate wall covering and firebox facing material.

Installing Hood

Flush Face Models

On flush face models, loosen screws (A) holding firebox top to face panel, slide hood flange between top and panel, then re-tighten screws.

Louvered Models

Remove upper louver. Place top hood flange on firebox, install three screws through firebox top into pilot holes in hood flange (B).

Optional Fresh Air Kit Installation Instructions

Air Door Installation for Vent Free Firebox Models:

Begin by removing the rectangular cutout on the left side of the firebox. Use gloves and sheet metal snips to create the opening for the Air Door assembly.

Optional Single Speed Blower Installation Instructions

Wiring

Appliance must be electrically grounded per local codes or National Electrical Code ANSI/NFPA 70.

JUNCTION BOX CONNECTIONS

Factory installed junction box on lower right side of firebox. Wiring fed to box and attached to receptacle.

Junction Box Wiring Installation Instructions

MAINTENANCE

Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing area at least twice a year.

Accessories

Fan Kit

Designed to provide forced air flow.

Variable Speed Control Kit

Wall mounted variable speed control for use with FBB5 blower

Brick Liners

Deluxe Firebox

Fresh Air Kit

Deluxe and Premium Fireboxes

Frame Kits

Standard 3-Piece Frame Kits Brass, Stainless Steel, or Hammered Pewter

Standard Hood

Brass hood = BR Stainless Steel = SS Hammered Pewter = HP

How To Order Repair Parts

Parts Not Under Warranty

Parts can be ordered via Service Person, Dealer, or Master Parts Distributor. See page for distributor list.

Warranty Parts

Warranty parts require proof of purchase and must be ordered by your Service Person or Dealer. Proof is required.

Empire Comfort Systems VFD36FB0L-1 Specifications

General IconGeneral
BrandEmpire Comfort Systems
ModelVFD36FB0L-1
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals