Step 8: Plug in and connect
the Branch current transformers
If the Vue has Branch CTs, open the clasps on
the CTs and place each clamp around the
non-neutral leg from the breaker that is to be
monitored. Then shut the clasps to secure the
CTs. Then, insert the screw terminal plugs into
the ports on the top of the energy monitor.
Note the port numbers. To avoid clutter,
unscrew the 22 AWG wires from the screw
terminals, cut them to size, and reattach them
ensuring the black and white wires match the
icons on the top of the Vue.
DANGER: The service
mains are energized!