L
N
Step 7(f): No empty breaker
and one Main CT
Common in European 1-phase homes
Uncommon in N. American homes
Secure the White (N)
, Red (L2), and Blue
(L3) wires from the wire harness to the
neutral block. Turn off a 15A MCB and
disconnect its wire. Connect that wire to the
Black (L1) wire from the harness and a
splicing wire with the wire nut. Then secure
the splicing Wire to the MCB.
Need help?
emporiaenergy.com/support
support@emporiaenergy.com
1-844-EMPORIA (367-6742)
A larger amp breaker may be
used if the gauge of the splicing
wire matches the existing gauge
wire from the breaker meeting the
national and regional codes