Commubox FXA291
Endress+Hauser 3
Wiring
Connection For computers: USB 1.1 and 2.0 compatible, 4-pole USB connector, type A
For transmitters: CDI connectors, short-circuit proof, reverse polarity protection
!
Note!
When delivered, the USB and adapter cables are fully wired on the box side and are fixed in place with a cable
gland.
Supply voltage Voltage range: from the USB interface of the PC, typically 5VDC
Field devices powered via VCC up to 100mW, reverse polarity protection
Intrinsically safe signal circuit For connecting an intrinsically safe circuit with explosion protection [EEx ia] IIC with:
Connection voltage: < 7 VDC
•U
m
: 260V
!
Note!
With Commubox FXA291 the intrinsically safe and the non-intrinsically safe connection are protected.
Therefore, you can connect an Ex device to the intrinsically safe side of Commubox FXA291 even if a non-Ex
device was connected before. The Commubox will not lose its Ex approval.
Performance characteristics
Communication Communication between computer and FXA291:
Baudrate: 2400 to 115.2k
Data bits: 8
Stop bits: 1
Parity: none
Start bits: 1
Duplex communication
Environment
Ambient temperature range -20 to +60 °C (-4 to +140 °F)
Storage temperature -40 to +85 °C (-40 to +185 °F)
Ingress protection IP51, NEMA/type 3
Relative humidity 0 % to 95 % (no condensation)