Owner's Guide
Printed in China
Toll Free 1 866 295 6775
www.energizerpower.com
WARNING:
This Unit employs Components that tend to produce arcs or sparks – To
prevent fire or explosion, do not install in compartments containing
batteries or flammable materials - SHOCK HAZARD. DO NOT OPEN.
CAUTION:
OUTPUT NON-SINUSOIDAL REFER TO MANUAL - Provided with integral
protection against overloads. To prevent fire, do not cover or obstruct
ventilation openings. Do not mount in Zero-Clearance compartment.
Overheating may result.
Notice :
The output of this device is not sinusoidal. It has a total harmonic distortion
of 30% percent and maximum single harmonic of 8 percent
EN100
3149458
Conforms to UL std. 458,
CSA std. C22.2 No. 107.1

Questions and Answers

  • E
    elizabeth48Jul 27, 2025
    What to do if Energizer EN100 AC product will not operate and the RED FAULT light is ON?
    • A
      Austin McclureJul 27, 2025
      If the AC product isn't working and the RED FAULT light is on, there could be several reasons: * The connected AC product's power rating exceeds the inverter's continuous power rating, causing an overload. Use a product with a lower power rating. * The AC product's starting surge exceeds the inverter's surge capability. Use a product with a starting surge within the inverter's capability. * The battery may be discharged, so recharge it. * The inverter may have overheated due to poor ventilation. Unplug it, let it cool for 15 minutes, and remove any obstructions. Also, for continuous operation, move the inverter to a cooler place, reduce the load, and restart it.
  • C
    Christina WalkerAug 7, 2025
    Why is the measured output of my Energizer EN100 inverter too low?
    • B
      Brian HuffAug 7, 2025
      If the measured inverter output is too low, here are a couple of potential causes: * If you're using a standard “average-reading” AC voltmeter, it might show a reading that's 5 to 15V lower than the actual output. The inverter's “modified sine wave” output requires a “true RMS” voltmeter for accurate measurements. * The battery voltage might be too low. In this case, recharge the battery.
  • H
    Heather GarciaAug 16, 2025
    How to fix Energizer EN100 Automobile Accessories when AC product will not operate and no inverter lights are ON?
    • C
      Christine StevensonAug 16, 2025
      If the AC product isn't working and no inverter lights are on, it could be due to: * A defective battery. Check the battery and replace it if necessary. * Loose connections. Ensure all connections are secure.

Summary

Introduction to Energizer EN100

Product Hazards and Warnings

Warnings about lethal AC power, heat, flammable environments, shock hazards, and fuses.

Operational Safety Guidelines

Operational Hazards and Cautions

Cautions regarding unit heat, flammable environments, and shock hazards during AC plug insertion.

Fire Risk and Fuse Safety

Caution against incorrect fuse replacement and the risk of fire.

Non-Sinusoidal Output and AC Power Cautions

Cautions for incompatible appliances and connecting live AC power.

Using the Energizer EN100 Inverter

Energizer EN100 Inverter Operation

Over-Voltage Caution for EN100

Troubleshooting Energizer EN100

No Power or Lights Issues

Addresses problems where the product will not operate and no indicator lights are on.

Low Output Voltage Measurement Issues

Explains why output voltage readings may appear low due to voltmeter type.

Red Fault Light Issues

Addresses problems where the product will not operate and the red fault light is illuminated.