www.energizerpower.com
Printed in China
WARNING:
This Unit employs Components that tend to produce arcs or sparks – To
prevent fire or explosion, do not install in compartments containing
batteries or flammable materials - SHOCK HAZARD. DO NOT OPEN.
Notice :
The output of this device is not sinusoidal. It has a total harmonic distortion
of 30% percent and maximum single harmonic of 8 percent
Toll Free: 1 866.295.6775
Owner's Guide
EN548
CAUTION:
OUTPUT NON-SINUSOIDAL REFER TO MANUAL - Provided with integral
protection against overloads. To prevent fire, do not cover or obstruct
ventilation openings. Do not mount in Zero-Clearance compartment.
Overheating may result.
©2016 Energizer Energizer and other marks, including graphics, are trademarks of Energizer
and used
u
nder license by PowerBright. All other trademarks, brand names or product names are the property of
their respective owners and are not affiliated with Energizer
or Bright Manufacturing LLC.
4010229
Conforms to UL Std.458,
Cert. to CSA Std. C22.2 No 107.1

Questions and Answers

  • J
    Jennifer GarciaAug 5, 2025
    What to do if the Energizer EN548 Power inverter RED FAULT light is ON?
    • J
      Jennifer FarmerAug 6, 2025
      If the red fault light on your Energizer Power inverter is on, it could be due to several reasons. The connected AC product might be rated at more than the inverter’s continuous power rating, causing an overload shutdown, so use a product with a lower power rating. Alternatively, the AC product might be rated less than the inverter’s surge capability; in that case, use a product with starting surge power within the inverter’s capability. Another reason could be a discharged battery, so try recharging it. Also, the inverter may have overheated due to poor ventilation; unplug it from the DC socket, allow it to cool for 15 minutes, and remove any objects covering it. If this doesn't help, move the inverter to a cooler place, reduce the load if continuous operation is required, and restart.
  • G
    Garrett LongAug 14, 2025
    How to fix an Energizer EN548 Power inverter when no lights are ON and the AC product doesn't operate?
    • N
      Nicole JohnstonAug 14, 2025
      If your Energizer Power inverter has no lights on and the AC product isn't working, the battery might be defective; check it and replace it if needed. Also, check for loose connections and ensure they are secure. The battery voltage could also be too low, so try recharging the battery.
  • A
    Amy GibsonAug 26, 2025
    Why is the measured output of my Energizer EN548 Power inverter too low?
    • T
      Todd TaylorAug 26, 2025
      If the measured output of your Energizer Power inverter is too low, it might be because a standard “average- reading” AC voltmeter was used to measure the output voltage, resulting in an apparent reading 5 to 15 V too low. The inverter’s “modified sine wave” output requires a “true RMS” voltmeter for accurate measurements.

Summary

Introduction

Important Safety Information

Safety Features

Inverter Features

Using the Inverter

Inverter Operation

Operating Guidelines

Details on voltage fall, automatic shutdown, and fault indication for inverter operation.

Battery Operating Time

Explains how operating time varies and provides tips for vehicle battery use.

Interference with Electronic Equipment

Television Interference

Discusses TV signal interference and mitigation steps.

Troubleshooting

Specifications

Warranty and Return

Warranty by PowerBright

Details what the limited warranty covers and its duration.

Warranty Exclusions

Lists conditions and circumstances not covered by the limited warranty.

Return Material Authorization Policy

Return Procedure

Outlines the steps for safely packaging and shipping a product for return.

Energizer EN548 Specifications

General IconGeneral
BrandEnergizer
ModelEN548
CategoryPower inverter
LanguageEnglish