PROBLEM: AC product will not operate, RED
FAULT
light ON.
Batteryvoltage is too low. Rechargebattery.
Possible cause Solution
ACproduct(s)connected
areratedatmorethanthe
inverter’scontinuous
power rating; overload
shutdownhas occurred.
Usea productwithapower
ratingless than the inverters
continuous power rating.
Batteryi s discharged. Rechargebattery.
Possible cause Solution
Unplug inverter from DC socket
and allow to cool for 15 minutes.
Remove objects covering unit.
Move the inverter to a cooler
place. Reduce load if continuous
operation is required. Restart.
The inverter has over
heated due to poor
ventilation and has shut
down.
Producte xceeds inverters
surgecapability.Useaproduct
withstarting surgepower
withintheinverterscapability.
ACproduct is rated less
thanthe inverters
continuouspowerrating;
high starting surge has
causedoverload
shutdown.