Overview

The Energizer eZV2200i is an ultra-quiet inverter generator designed for portable power needs. It features a compact and durable design, making it suitable for recreational and residential use.

Function Description:

The eZV2200i operates as an inverter generator, producing clean and stable AC power suitable for sensitive electronics. It also offers a DC output for charging 12V batteries. The generator is designed for outdoor use and can be operated in parallel with another compatible Energizer i-series inverter generator using an optional parallel kit for increased power output. Its "EcoMode" feature helps minimize fuel consumption by dynamically adjusting engine speed to meet the electrical load, idling when loads are disconnected.

Important Technical Specifications:

  • Model Name: eZV2200i
  • Engine Type: 4-stroke, overhead valve, single cylinder, forced-air cooling
  • Engine Displacement: 80 cc
  • Bore x Stroke: 1.91 x 1.69 in. (48.6mm x 43.0mm)
  • Engine Speed: 5300 rpm
  • Compression Ratio: 7.6:1
  • Ignition System: Full transistor
  • Spark Plug: E6RTC
  • Spark Plug Gap: 0.028-0.031 in (0.7-0.8mm)
  • Start System: Recoil starter
  • Fuel Type: Unleaded Gasoline (Octane 85 or higher, ethanol content less than 10%)
  • Fuel Tank Volume: 1.2 gal / 4.5 L
  • Oil Capacity: 12 fl. Oz / 0.35 L
  • Oil Type: SAE 10W-30 or SAE synthetic 5W-30
  • Rated Frequency: 60Hz
  • Rated Voltage: 120V
  • Rated Current: 15A
  • Rated Output Power: 1800W
  • Max. Output Power: 2200W
  • DC Output: 12V/8A
  • Run Time (100% load): 3.2 hours @ 1800W
  • Working Ambient Temperature: 5°F to 104°F (-15°C to 40°C)
  • Max. Altitude: 3280 ft. / 1000m
  • Sound Power Level at 7m: 61-70dB(A) (measured with EcoMode ON)
  • Dimensions (L x W x H): 18.5" x 10.2" x 15.7"
  • Net Weight: 46 lbs / 24kg
  • Grounding: Floating neutral
  • Certifications: Meets EPA and California Air Resource Board (CARB) clean air standards.

Usage Features:

  • Control Panel: Features a power knob (combination power/fuel/choke), EcoMode switch, 12V 8A DC outlet, 5V 1.5A USB port, 120V 15A AC duplex (5-20) outlets, and parallel connection ports.
  • Indicators: Includes a Low Oil Indicator (red), Overload Indicator (red), and Ready to Use Indicator (green) to provide operational status and alerts.
  • Starting: Manual recoil start. The power knob has CHOKE and RUN positions for cold and warm engine starts, respectively.
  • AC Applications: Connect electrical appliances to the 120V AC outlets. It's recommended to turn EcoMode OFF before connecting high-load devices and then ON once they reach running power.
  • DC Applications: The 12V DC receptacle is used for charging 12V batteries. EcoMode should be OFF during DC operation. It can be used simultaneously with AC power, but the total power for AC and DC should not exceed the generator's limits.
  • Parallel Operation: Two compatible Energizer i-series inverter generators can be connected in parallel using an optional parallel kit to double the power output. Generators must be OFF before connecting the parallel cable.
  • Safety Features: Equipped with an AC circuit breaker and a DC circuit breaker that automatically shut off if current limits are exceeded or the charging circuit is overloaded. The low oil alert system automatically shuts down the engine if oil levels are insufficient to prevent damage.
  • High Altitude Operation: The carburetor may require modification (changing main-nozzle or adjusting idling-screw) for operation above 3280 feet (1000 meters) to maintain performance and prevent engine damage.

Maintenance Features:

  • Maintenance Schedule: A detailed schedule is provided for regular maintenance tasks, including checks for engine oil level, air filter, fuel line, sediment cup, spark arrester, and spark plug.
  • Oil Change: Recommended to change engine oil after the first 5 hours or first month, then every 100 hours or 12 months (whichever comes first). SAE 10W-30 or SAE synthetic 5W-30 oil is recommended. The process involves draining old oil and refilling to the maximum mark on the dipstick.
  • Air Filter Cleaning: The air filter should be inspected before each use and cleaned/replaced every 50 hours or 6 months. Cleaning involves removing, washing with soap and water or solvent, oiling with clean engine oil, and reinstalling.
  • Spark Plug Service: The spark plug should be inspected/cleaned every 100 hours or 12 months, and replaced every 300 hours. This involves removing, inspecting for cracks/chips, cleaning carbon deposits, measuring and adjusting the gap (0.028-0.031in), and reinstalling.
  • Spark Arrester Maintenance: The spark arrester should be inspected/cleaned every 100 hours or 12 months to remove carbon deposits.
  • Fuel Filter Maintenance: The fuel filter should be cleaned every 50 hours or 6 months. This involves removing the fuel cap and filter, cleaning the filter with solvent, wiping it dry, and reinserting.
  • Storage: Recommendations for short-term (less than 1 month) and long-term (1 month to 1 year, or 1 year or more) storage are provided. This includes draining fuel, adding fuel stabilizer, changing oil, and preparing the engine for extended periods of inactivity to prevent corrosion.
  • Emission Control System: The generator features an emission control system to reduce carbon monoxide, NOx, hydrocarbons, and evaporative fuel emissions, meeting EPA and CARB standards. Regular maintenance is crucial for maintaining these standards.

Energizer eZV2200i Specifications

General IconGeneral
BrandEnergizer
ModeleZV2200i
CategoryPortable Generator
LanguageEnglish

Related product manuals