Series | ZU4 |
---|---|
Maximum Operating Pressure (bar) | 700 |
Power Source | Electric |
Maximum Pressure (psi) | 10000 |
Motor Size (kW) | 0.75 |
Provides output flow rate, motor electrical specifications, and sound level.
Illustrates the relationship between flow rate, current, and pressure.
Details the installation of the breather cap for the reservoir.
Provides dimensions for mounting the pump to a fixed surface.
Details electrical connection requirements and safety precautions.
Instructions for checking and adding hydraulic fluid to the reservoir.
Guidance on applying Teflon tape and connecting hydraulic hoses.
Instructions for operating the VM32 manual valve.
Instructions for operating the VM33/VM43 manual valve.
How to operate the pump using a 1 or 2 button pendant.
Operating pumps with VE33/VE43 valves and a 3-button pendant.
Operating pumps with VE32 valve and a 3-button pendant.
Operating pumps with VE32D valve and a 1-button pendant.
Instructions for operating valves using a foot switch.
How to use automatic pump operation with a pressure transducer.
How to use automatic pump operation with a pressure switch.
Procedure for adjusting the user-adjustable relief valve.
Explains the basic layout and components of the LCD screen.
Details the function of the four buttons on the control board.
Lists and describes the various menus accessible via the LCD.
Procedure for clearing fault messages from the LCD display.
Describes the condition and display for low voltage warnings.
Shows the standard 'OK' status and pressure reading.
Allows setting the trigger pressure for valve shift or motor shut-off.
Allows selection of pressure units (PSI, BAR, MPa).
Displays motor hours and on/off cycle counts.
Displays hours operated in low-voltage conditions.
Displays advance solenoid hours and cycle counts.
Displays retract solenoid hours and cycle counts.
Enables local operation mode, bypassing pendant controls.
Allows changing the display language of the LCD.
Helps troubleshoot pendant problems by displaying button signals.
Configures automatic pump control based on pressure limits.
Sets the high-pressure limit for motor/valve de-energization.
Sets the low-pressure limit for motor/valve re-energization.
Allows adjusting the LCD pressure value to match a master gauge.
Procedure for checking and maintaining the hydraulic oil level.
Instructions for changing hydraulic oil and cleaning the reservoir.
Procedure for replacing the return line filter element.
Instructions for replacing worn motor brushes.
Details installation of the pressure transducer for LCD electric pumps.
Details installation of the pressure switch for LCD electric pumps.