EasyManua.ls Logo

Envirco MAC 10 LEDC/IQ Standard - User Manual

Envirco MAC 10 LEDC/IQ Standard
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ENVIRCO Technical Support: 800-884-0002
MAC 10
®
LEDC/IQ
Fan Filter Unit
Standard, RSR, RSRE, & RSRC Models
OPERATION & MAINTENANCE MANUAL

Questions and Answers

  • S
    shelby87Aug 2, 2025
    Why is my Envirco Water Filtration System unit not running?
    • A
      Abigail JeffersonAug 2, 2025
      The Envirco Water Filtration System might not be running due to several reasons. It could be due to no power; confirm the primary voltage. It could also be due to bad electronics such as a faulty switch, transformer, or board; check these electrical components for functionality. A faulty motor harness could also be the reason; if voltage is found at the control board but not at the motor, replace the motor harness. The motor itself might be faulty; if voltages are correct on the board and motor, but the motor still does not run, reference the troubleshooting section for mechanical issues and perform the steps. A mechanical issue could also be the cause. In addition, network control issues could be the reason; refer to the Unit Not Running troubleshooting section.
  • G
    gomezjuanAug 5, 2025
    What to do if my Envirco Water Filtration System has low airflow?
    • C
      Caleb PotterAug 6, 2025
      If your Envirco Water Filtration System has low airflow, check the filter media. The pre-filter can be cleaned or replaced, and the HEPA/ULPA media may need to be replaced. Verify the air supply is adequate to provide the airflow required; it is recommended to start fan filter units before air handlers. Also, check that the unit is running and reference the troubleshooting for unit not running and mechanical issues. Increase the speed control setting to the fan filter units. Finally, verify there are no environmental restrictions.
  • R
    Rachel AndersenAug 10, 2025
    What to do if my Envirco Water Filtration System has mechanical issues?
    • D
      danielwardAug 10, 2025
      If you notice mechanical issues with your Envirco Water Filtration System such as a broken motor mount, broken inlet ring connections, damaged blower wheel, wheel fallen off motor shaft, or failing motor bearings, contact Envirco for further assistance.
  • C
    cmackAug 14, 2025
    What causes high airflow in my Envirco Water Filtration System?
    • A
      Amy JacksonAug 14, 2025
      High airflow in your Envirco Water Filtration System can be caused by an air supply issue. Verify that the air supply is adequate to provide the airflow required and recommend starting fan filter units before air handlers. It can also be caused by a high-speed setting; decrease the speed control setting to the fan filter units.
  • B
    Bradley WilliamsAug 19, 2025
    What to do if the indicator light is not on for my Envirco Water Filtration System?
    • A
      anthony11Aug 19, 2025
      If the indicator light is not on for your Envirco Water Filtration System, it may be due to no power; if there is an issue with the electrical components, the indicator lights will not function. It could also be due to a non-working light; it is recommended to unscrew the bezel, take out the bulb, turn it 180 degrees, and reinsert the bulb. Another reason could be the pressure switch closure; the pressure switch must be adjusted when first installed to work for that application’s specific conditions.
  • E
    Elizabeth EwingAug 23, 2025
    What causes a leaking filter in my Envirco Water Filtration System?
    • K
      Katherine YoungAug 23, 2025
      A leaking filter in your Envirco Water Filtration System can be caused by a damaged filter; inspect the filter for any physical damage before installing it in the ceiling. It can also be caused by improper installation or bypass; refer to TN1012 to help determine if the filter is leaking or if there is bypass coming from another location.
  • M
    markhayesAug 27, 2025
    Why is my Envirco Water Filtration System acting erratically or unable to balance?
    • A
      ashley84Aug 27, 2025
      If your Envirco Water Filtration System is acting erratically or is unable to balance, it could be due to an incorrect motor program. Constant volume programming available to the MAC10 IQ is incompatible with ducted, pressurized air applications for use in series with CAV or VAV devices. Also, providing too much or too little air to the fan filter units can cause issues.

Summary

Safety and Handling

General Safety Precautions

Safety guidelines for installation and maintenance to prevent fire, shock, or injury.

Unit Labels and Handling

Guidelines for identifying, handling, and recording unit labels and serial numbers for proper part ordering.

Installation Procedures

Unboxing and Initial Inspection

Instructions for safely unboxing, inspecting the unit for damage, and verifying voltage before installation.

OSHPD Seismic Installation

Procedures for installing seismic hanger brackets according to OSHPD certification requirements.

Ducting and Mounting Accessories

Guides for installing duct collars and sheetrock adapter frames for ceiling mounting.

Unit Configurations and Control

MAC10 Model Styles

Explains the four main model styles and their room-side accessibility features.

Control Systems

Details the different control box options, wiring, and features for unit operation.

Service and Maintenance

Filter Replacement Procedures

Step-by-step instructions for replacing pre-filters, HEPA/ULPA, and RSR/E/C filters.

Motor Service Procedures

Guides for removing and installing motors for various MAC10 models, including IQ and LEDC variants.

Specifications and Troubleshooting

Electrical and Communication Specs

Technical specifications for electrical input, frequency, power consumption, and communication protocols.

Troubleshooting Common Issues

Comprehensive guide to diagnose and resolve common issues such as unit not running, control problems, and airflow.

Replacement Parts and Testing

Replacement Parts Lists

Lists of common replacement parts, including filters, motors, and control components, with part numbers.

Performance Testing

Recommendations and procedures for re-testing the unit after installation to ensure proper performance.

Warranty Information

Limited Warranty Terms

Details ENVIRCO's limited warranty terms, exclusions, and buyer responsibilities.