TECHNICAL MANUAL
SUSPENDED PARTICULATE
BETA GAUGE MONITOR
MP101M
- APRIL 2014 -
111 bd Robespierre, 78300 POISSY - -TEL. 33(0)-1.39.22.38.00 – FAX 33(0)-1.39 65.38.08
http://www.environnement-sa.com
GENERAL
CHARACTERISTICS
PRINCIPLE OF
OPERATION
OPERATION
PREVENTIVE
MAINTENANCE
CORRECTIVE
MAINTENANCE
APPENDIX

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Environnement MP101M and is the answer not in the manual?

Environnement MP101M Specifications

General IconGeneral
BrandEnvironnement
ModelMP101M
CategoryMonitor
LanguageEnglish

Summary

Chapter 0 Safety Guidelines

0.1 Warning

General warnings regarding radioactive sources and operational safety.

0.2 Reminder of Principal Statutory Technical Precautions

Statutory precautions for radiation protection, employer responsibilities.

0.3 Presentation of Equipment

Description of the beta gauge source holder and safety devices.

0.4 Risks Assessments

Measurements of dose rate and control of contamination related to radioactive sources.

0.5 Risk Analyses

Analysis of external and internal exposure risks, permissible dose limits.

0.6 Radiation Protection Recommendations

Recommendations for signals, staff information, and interventions on source holders.

0.7 Safety Instructions - Example

Example safety instructions for handling radioactive sources and equipment.

0.8 Technical Controls of Radioprotection

Recommendations for periodic technical checking of radioprotection.

0.9 End of Life of the Analyzer

Guidance on local rules for end-of-life radioactive material and equipment.

Chapter 1 General – Characteristics

1.1. General

General presentation and description of the MP101M system.

1.2. Characteristics

Technical, operating, storage, and installation characteristics of the MP101M.

1.2.5. Certifications

Details on USEPA and EN12341 designations for the MP101M analyzer.

Chapter 2 Principle of Operation

2.1. Beta Gauge Principle (Figure 2–1 and Figure 2–2)

Explanation of the beta gauge principle using radioactive source and detector.

2.2. Flow Regulation Principle

Principles of constant volume flow rate control and compensation.

2.3. Acquisition and Processing of Measurement Parameters

How temperature, pressure, and detection signals are processed.

2.4. Organization of Measurements

Description of measurement organization into scan periods and cycles (cyclic, periodic).

2.5. Regulated Sampling Tube (RST)

Details on the regulated sampling tube (RST) line and its components.

Chapter 3 Operation

3.1 Initial Start-Up

Preliminary operations and steps for starting up the MP101M unit.

3.2 Programming the MP101M

How to select and modify programmable parameters and operating parameters.

3.3 Description of the Different Screens

Detailed descriptions of the instrument's screens: Main Menu, Measurement, Calibration, Configuration, etc.

Chapter 4 Preventive Maintenance

4.1. Safety Instructions

Essential safety instructions to follow during analyzer maintenance.

4.2. Maintenance Calendar

Schedule of routine maintenance operations and their periodicity.

4.3. Maintenance Operation Sheets

Specific sheets detailing maintenance operations for various components.

4.4. Equipment Necessary for Maintenance

List of recommended spare parts and equipment required for maintenance.

Chapter 5 Corrective Maintenance

5.1. List of Faults and Corrective Actions

Table summarizing common faults, their causes, and possible corrective actions.

5.2. Module Board of MP101M

Configuration details for the MP101M module board, including jumper settings.

5.3. General Connection Diagram

Wiring diagram illustrating electrical connections and component layout.

6 Appendices

Appendix 1 : ESTEL BOARD

Information regarding the ESTEL board, its functions, and configuration.

Appendix 2 : DNP-ARM7 BOARD

Details about the DNP-ARM7 board, its technical characteristics, and configuration.