SHOULD YOU ENCOUNTER ANY PROBLEMS
INSTALLING THIS UNIT, CALL US ON:
ECO
2
Twin Installation Instructions
Twin Spigot
This addition to the fixing instructions explains the methodology of installing the twin spigot system.
This variation to the ECO
2
Loft is necessary where:
The hallway is very small, particularly when there is limited heating in the house
The loft hatch fills the hallway ceiling
Air is required to be diffused into a remote zone, such as a bedroom
Cut two 105mm holes in the ceiling in the positions chosen where air is required to be delivered.
Use the distance from the ECO
2
Loft Unit to each hole to balance/favour airflow:
i. Equal air supply required - diffusers equidistant from unit
ii. More air supply required in hallway - short run to diffuser in the hall
(This is the recommended method of installation)
Connect the flexi ducting to the twin spigot and hold in position with a cable tie on each outlet.
ECO
2
Twin Installation
Example of installation: More air is required in hall - shorter run
HALL
Vent One
BEDROOM
Vent Two
Contents for unit with heater
1 x Fixing kit
1 x Unswitched fuse spur
2 x Mini diffuser
1 x Cable tie
2m x 3m x 100mm Flexi duct
Additional contents for
unit with heater
1 x Heater enable switch

Other manuals for Envirovent Mr Venty ECO2 Loftight Twin

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Envirovent Mr Venty ECO2 Loftight Twin and is the answer not in the manual?

Envirovent Mr Venty ECO2 Loftight Twin Specifications

General IconGeneral
BrandEnvirovent
ModelMr Venty ECO2 Loftight Twin
CategoryVentilation
LanguageEnglish

Related product manuals