52
EN Commissioning
7. Commissioning
Water splashes Time
Switch no.. 1 2 3 4 5
Number of
splashes
Time
interval
OFF OFF OFF OFF OFF 4 60 min
ON OFF OFF OFF OFF 2 60 min
OFF ON OFF OFF OFF 3 60 min
ON ON OFF OFF OFF 1 60 min
OFF OFF ON OFF OFF 4 30 min
ON OFF ON OFF OFF 2 30 min
OFF ON ON OFF OFF 3 30 min
ON ON ON OFF OFF 1 30 min
OFF OFF OFF ON OFF 4 45 min
ON OFF OFF ON OFF 2 45 min
OFF ON OFF ON OFF 3 45 min
ON ON OFF ON OFF 1 45 min
OFF OFF ON ON OFF 4 15 min
ON OFF ON ON OFF 2 15 min
OFF ON ON ON OFF 3 15 min
ON ON ON ON OFF 1 15 min
1
ON
2 3 4 5
The settings for water splash events are made with the DIP-Switch on the main board.
ATTENTION: Make settings (DIP-Switch) only with the system disconnected from power!
► Settings for the number of splashes and time intervals
► DIP-Switch
A B
DIP-Switch
DIP-Switch - complete overview of settings
A. Position ON
B. Position OFF