53
Commissioning
► Switching to an external push-button
Using the DIP-switch no. 5 you can set the operation control to be made from an exter-
nal push-button.
Switch 5 „ON“ - control from an external push-button. Settings made with
switches 3 and 4 remain inactive.
Switch 5 „OFF“ - time intervals will be controlled as per settings of the
switches 3 and 4, as indicated in the general table.
Switch the mill wheel on using the ON/OFF switch.
The programme procedure starts.
To use an optional remote start button, DIP switch 5 must be set to ON.
After every infusion, wait approx. 10 minutes until the next infusion. Only then have the sauna
stones heated up properly.
HINWEIS
Only switch the mill on when the heater and sauna stones are at operating tempera-
ture. This takes approx. 45 minutes.
► Light and fan
The light and fan are N/O contacts.
As soon as the connection is established, they function as follows:
The light is switched on approx. 1.5 minutes before an infusion cycle.
After each infusion cycle, the fan switches on after a time delay of approx. 5 seconds for a
duration of approx. 20 seconds.
After the last infusion of a cycle and the fan operation, the light switches o together with
the fan.