For use in normal environments.
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu,
Cork, T12 W665, Ireland
sales@ephcontrols.com www.ephcontrols.com
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
sales@ephcontrols.co.uk www.ephcontrols.co.uk
R17-RF - 1 Zone RF Timeswitch
Installation Instructions
Page 1 of 2
Before commencing any work on the electrical connections, you must rst disconnect the timeswitch
from the mains. None of the 230V connections must be live until the installation has been completed
and the housing is closed. Only qualied electricians or authorised service sta are permitted to open
the timeswitch. Disconnect from mains supply in the event of any damage to any buttons.
There are parts that carry mains voltage behind the cover. The timeswitch must not be left unsupervised
when open. (Prevent non specialists and especially children from gaining access to it.)
If the timeswitch is used in a way not specied by the manufacturer, its safety may be impaired.
Ensure that this wireless enabled timeswitch is installed 1 metre from any metalic object, television,
radio or wireless internet transmitter.
Prior to setting the timeswitch, it is neccessary to complete all required settings described in this section.
Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.
CAUTION! Installation and connection should only be carried out by a qualied
person and in accordance with national wiring regulations.
Type
EN60730
1C
IP20
EN60529
50
°C
0
122
°F
32
5-95%RH
160.5
100
This timeswitch can be mounted in the following ways: 1. Directly wall mounted 2. Mounted to a recessed conduit box
This 1 zone RF timeswitch is designed to provide
ON/OFF control for 1 zone, with the value added
application of in built frost protection.
Important: Keep this document
1
3
4
5 6
2
20170302_AW1077_R17-RF_InsIns_JW
Question and Answer IconNeed help?

Do you have a question about the EPH R17-RF and is the answer not in the manual?

EPH R17-RF Specifications

General IconGeneral
BrandEPH
ModelR17-RF
CategoryTimer
LanguageEnglish

Summary

Installation Instructions

Safety Precautions and Warnings

Critical safety guidelines and warnings for qualified installers during timeswitch installation and connection.

Mounting Methods

Information on the two approved methods for mounting the timeswitch: directly to a wall or to a recessed conduit box.

Timeswitch Configuration and Operation

Factory Default Settings

Overview of the timeswitch's pre-configured operational settings.

Specifications and Wiring

Technical specifications and essential wiring diagrams for the timeswitch installation.

Setting the Date and Time

Step-by-step guide to configure the date, time, and program settings for the timeswitch.

Frost Protection Function

Instructions on how to enable and configure the frost protection feature for pipe safety.

Master Reset Procedure

Procedure to perform a master reset on the timeswitch, requiring reprogramming.