45
Function classification: Additional functions
Function Command
Epson Web
Control Setting
Availability
Setting Value/Response Value
Execute or Release A/V Mute/
Acquire status
MUTE x1 ✔ -
MUTE? ✔ -
Parameter/Return code ON: Execute A/V Mute
OFF: Release A/V Mute
INIT(settings only)
Execute or Release Freeze/
Acquire status
FREEZE x1 ✔ -
FREEZE? ✔ -
Parameter/Return code ON: Execute Freeze
OFF: Release Freeze
INIT(settings only)
INC: Increase the setting value/DEC: Decrease the setting value/INIT: Return to defaults
Function classification: Configuration
Function Command
Epson Web
Control Setting
Availability
Setting Value/Response Value
Horizontal Reverse Settings/
Acquire settings
HREVERSE x1 ✔ -
HREVERSE? ✔ -
Parameter/Return code ON: Horizontal Reverse status
OFF: Normal
INIT (settings only)
Vertical Reverse Settings/
Acquire settings
VREVERSE x1 ✔ -
VREVERSE? ✔ -
Parameter/Return code ON: Vertical Reverse status
OFF: Normal
INIT (settings only)
Reset All Config INITALL2 x1 ✔ -
Parameter/Return code x1: Reset target (Hex)
bit 15: Reserved
bit 14: Reserved
bit 13: Reserved
bit 12: Reserved
bit 11: Reserved
bit 10: Memory
bit 9: Multi-Projection
bit 8: Reserved
bit 7: Reserved
bit 6: Network
bit 5: Management
bit 4: Operation
bit 3: Display
bit 2: Installation
bit 1: Signal I/O
bit 0: Image
Set as 0: Do not Reset
Set as 1: Reset
*This command is defined by bit assignment.
Communication Speed
Settings/Acquire settings
SPEED x1 - -
Parameter 00: 9600bps
01: 19200bps
02: 38400bps
03: 57600bps
INIT
SPEED? - -
Return code 00: 9600bps
01: 19200bps
02: 38400bps
03: 57600bps
Projector ID
Settings/Acquire settings
Base Unit ID
Settings/Acquire settings
PROJID x1 ✔ -
PROJID? ✔ -
Parameter/Return code 00: Off
01-09: ID1-ID9
INIT (settings only)