ESC/VP21 Command User's Guide for Business Projectors
6 of 24
4.2.Power on state (operation indicator is in green)
All commands are executable.
4.3.Error Status
A projector returns the error status when a projector receives "ERR?" command.
The following projectors can return the error status while the projectors become the cool-downs status at an error and the projectors become
the error status after cooling down.
EMP-1700/1705/1710/1715, 6000/6100/6110/6010, 1815/1810/1825, S5/X5/83/822, 260/280, 400W
EB-G5000/G5100/G5150/G5200W/G5300/G5350
And later models.
[The other models except the above models]
The models except the above models can return the error status while the projectors become the cool-downs status at an error.
The following table shows the return codes and the meaning of error status.
S5/X5/83/822/83+/822+/
EX90
about 4.1W about 5W
(only 83/822)
260/280 about 4.1W about 4.1W
(only 280)
6110/6010 about 0.4W about 10.4W
400W about 4.2W about 4.9W
G5350/G5300/G5150/
G5100/G5200W/G5000
about 0.4W about 10W
Command Returne code
ERR?
00 :There is no error or the error is recovered
01 : Fan error
03 : Lamp failure at power on
04 : High internal temperature error
06 : Lamp error
07 : Open Lamp cover door error
08 : Cinema filter error
09 : Electric dual-layered capacitor is disconnected
0A : Auto iris error
0B : Subsystem Error
0C : Low air flow error
0D : Air filter air flow sensor error
0E : Power supply unit error (Ballast)