Modello - Modèle - Model
Modell - Modelo
MULTIFRESH PLUS MODULAR
MULTIFRESH PLUS MODULAR WL
Fabbricante - Constructeur
Manufacturer - Hersteller
Fabricante
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
PAGE
21/60
N° DOC
UM000472
20. MEANING OF THE LEDS
21. MALFUNCTION AND REMEDIES
Most of the functioning inconveniences are generally due to defective electrical connections.
These problems can usually be solved on the place.
THE UNIT DOES NOT START
POSSIBLE CAUSE SOLUTION AUTHORISED STAFF
Check that there is voltage at the wall socket
Insert the plug User
Check that the unit is properly plugged
Insert the plug correctly User
Check that the plug cord is broken
Replace the plug cable Technical support
If power failure is not due to any of the above causes, call the nearest after-sales service immediately, empty the cabinet and store the foods in
coldrooms or refrigerators that may ensure their preservation temperature.
THE INTERNAL TEMPERATURE IS NOT COLD ENOUGH
POSSIBLE CAUSE SOLUTION AUTHORISED STAFF
Check door is perfectly closed Close correctly User
Make sure that the cabinet has been filled correctly Load the product correctly User
Check that the unit is not adjacent to sources of heat Position the equipment correctly User
Check the temperature setting Set the correct temperature Technical support
Check that behind the cabinet air can properly circulate Position the equipment correctly User
If failure to cool should is not due to any of the above reasons it it persists on even after the above checks, resort to the nearest after-sales
service.
THE UNIT IS NOISY
POSSIBLE CAUSE SOLUTION AUTHORISED STAFF
Check that all the bolts and nuts are properly fastened Screw in the screws User
Check that the unit is placed on an even surface Position the equipment correctly User
Check if any pipe or fan is in contact with any other part of the body Switch off the counter and distance
the parts in contact in the event the
problem persists, contact the support
service.
Technical support
Should the inconvenience persist, contact the nearest after-sales service.
LED MODE MEANING
ON Active compressor
Flashing Delay against close starts
ON Defrosting in progress
Flashing Dripping in progress
ON Fans on
Flashing Fans start delay in progress
ON A temperature alarm activated
ON Continuous cycle in progress
LED MODE MEANING
ON Light on
ON Auxiliary active
ON Unit of measurement
Flashing Programming
ECO
ON Energy saving in corso
°C