-7-
INFORMATIONS ABOUT USE
ENGLISH
SAFETY WARNINGS FOR THE APPLIANCES USING
R600a COOLING FLUID (ISOBUTANE)
Isobutane is a natural gas that doesn’t affect the environment but is inammable. It is therefore in-
dispensable to check that the cooling circuit tubing is not damaged before connecting the equipment
to the mains. For every 8gr. of cooling uid, the installation location must have a minimum volume
of 1 cubic metre. The amount of cooling uid in the appliance is indicated on the technical data plate
on the back. Leakage of cooling uid: avoid naked ames or over sources of ignition at the seat of the
leakage. Be careful not to damage the cooling uid circuit during positioning , installation or cleaning.
Avoid ames or sparks inside the equipment.
Warning! Do not damage the cooling uid circuit
Warning! Do not damage walls of the machine: the cooling uid circuit may damage
Warning! In case of damaged cooling uid circuit, do not start the machine and refer to a service centre.
Warning! Do not obstruct the equipment’s air vents/grills. The appliance must be at least 10 cm
from the walls.
Warning! Do not use electrical appliances inside the food storage compartments of the appliance,
unless they are of the type recommended by the manufacturer.
Warning! Do not store explosive substences such as aerosol cans with ammable propellant in this aplliance.
INSTALLATION
Take out packaging and clean all the cabinet using warm water together with 5% of neutral soap then
dry it with a soft cloth; for the glass parts only use specic products, avoiding the use of water which
can leave on the glasses limestone residues.
Warning!
Keep a distance from the wall of 10 cm. at least.
Cabinet must be installed on a perfectly even surface (please settle
the adjustable feet) , far away from any heat source (radiators,
stoves, etc) including sun rays.
Good running of the cabinet can be compromised in cases where the
airow is disturbed (wind, ventilators, air conditioning outlets, etc).
Smooth running of the cabinet is assisted when sufcient
air is permitted to ow through the bottom of the unit; it is
very important that the grills at the base are kept uncovered.
Do not expose the cabinet to rain.
Warning!
Install and position the unit in such a way so as to allow
easy access to the power socket.
Never use electrical equipment in the refrigerated
compartment.
Never place containers of liquid on or immediately above
the ticket counter; should the content spill out, it would
damage the counter.
10
cm