16
01
Technical specications
General
Rated voltage/frequency:
220 – 240 V ~ / 50 Hz
Rated input: 2400 W
Rated pressure: 11 MPa
Max. allowable pressure: 16 MPa
Max. inlet water pressure: 1 MPa
Rated ow: 7.66 l/min
Max. rated ow: 8.66 l/min
Rated temperature: 50°C
Gun kickback force at max. pressure: < 2.5 Nm
Protection class:
I /
Degree of protection: IPX5
Weight: 23.5 kg
Dimensions: 441 X 479 X 864 mm
High pressure hose
Allowable pressure: 20 MPa
Maximum temperature: 60 °C
Length: 10 m
Water hose (not supplied)
Quality: Reinforced hose
Diameter: min. Ø 12.7 mm (½“)
Length: max. 10 m
Sound level
Sound pressure level L
pA
73.9 dB(A)
Uncertainty K
pA
2.50 dB(A)
Measured sound power level L
WA
85.4 dB(A)
Uncertainty K
WA
2.50 dB(A)
Guaranteed sound power level L
WA
(acc. to 2000/14/EC amended by
2005/88/EC)
88 dB(A)
Vibration level
Declared vibration emission value a
hd
: <2.5 m/s²
Uncertainty K: 1.0 m/s²
5063022018885-EBPW2400-PressureWasher-UM-V02.indd 165063022018885-EBPW2400-PressureWasher-UM-V02.indd 16 08-11-2022 16:26:4308-11-2022 16:26:43
17
The sound values have been determined according to noise test code given in EN
60335-2-79, using the basic standards ISO 3744 and ISO 11203.
The sound intensity level for the operator may exceed 80 dB(A) and ear protection
measures are necessary.
The declared vibration value has been measured in accordance with a standard test
method (according to EN 60335-2-79) and may be used for comparing one machine with
another. The declared vibration value may also be used in a preliminary assessment
of exposure.
WARNING!
Depending on the actual use of the machine the vibration values
can differ from the declared total! Adopt proper measures to protect yourself
against vibration exposures. Take the whole work process including times
the machine is running under no load or switched off into consideration.
Proper measures include among others regular maintenance and care
of the machine and cutting attachments, keeping hands warm, periodical
breaks and proper planning of work processes.
02
Symbols
Onthemachine,theratinglabelandwithintheseinstructionsyouwillndamongothers
the following symbols and abbreviations. Familiarize yourself with them to reduce
hazards like personal injuries and damage to property.
V~ Volt, (alternating
voltage)
kg Kilogram
Hz Hertz dB(A) Decibel (A-rated)
W Watt m/s² Metres per second squared
/min or min
-1
Per minute MPa Mega Pascal, pressure unit
mm Millimetre bar Pressure unit
P
rated
Rated pressure Q
rated
Ratedow
P
max
Allowable pressure Q
max
Maxow
p
IN MAX
Max inlet water pressure
IPX5 The machine is protected against water (out of a nozzle) from all
directions.
yyWxx Manufacturingdatecode;yearofmanufacturing(20yy)andweekof
manufacturing (Wxx).
EBPW2400 EB_BrandName;PW_Pressurewasher;2400_Power
5063022018885-EBPW2400-PressureWasher-UM-V02.indd 175063022018885-EBPW2400-PressureWasher-UM-V02.indd 17 08-11-2022 16:26:4308-11-2022 16:26:43
96454_IM_Erbauer 2400_EU.indb 1696454_IM_Erbauer 2400_EU.indb 16 2023/3/27 上午10:562023/3/27 上午10:56