Arguments:
File nameThe name of the configuration file. Note that the
configuration file that PEM has configured is named primary.
Default Setting
None.
Command Usage
When using this command, the currently permanent configuration file, if any,
will lose its status of being permanent.
Example:
efn# config make_permanent test
13.9.6 set main_board
Use this command to set the alarm limit for the temperature of the main board.
Use the command reset main_board to reset to default values.
Syntax
set main_board temperature_limit <limit>
Arguments:
<limit>Limit for the temperature, setting when a temperature alarm
is issued. Range 20 to 80 °C.
Default Setting
80
Example:
efn# set main_board temperature_limit 50