Glossary
12.2 Major Severity Alarms
12.2.1 ElnOverheat
MIB: ERICSSON-ELN-TRAP-MIB
Description: A temperature has exceeded the temperature limit in the switch.
The reason can be fan failure, too high ambient temperature or both.
Corrective Actions:
- Ensure that the ambient temperature is within the specified operating range.
- Check that the fan is working and the air inlets and outlets for the fans are
not blocked.
Valid from EDA 2.2 R3A
Parameters:
No. Parameter Parameter Value
1 Managed object
class
EFN324f or ELN220
2 Managed object
Instance
EFN324=<IP address> or
ELN220=<IP address>
3 Sequence number Alarm sequence number
4 Perceived severity Major
5 Event time Time stamp from real time clock, retrieved
through a SNTP server
6 Event type
equipmentAlarm
7 Probable cause
temperatureUnacceptable
8 Temperature Value The temperature of the node
9 Temperature Limit The temperature threshold value
Clearing Alarms
ElnOverheatOK, ElnRestart