12.3 Warning Severity Alarms
12.3.1 ElnLinkDown
MIB: ERICSSON-ELN-TRAP-MIB
Description: A link to one of the ports is not operational.
Corrective Actions:
- Ensure that the node connected to the other end of the link is operational.
- Check the physical link (optical or electrical) for damage and replace if
necessary.
Valid from EDA 2.2 R3A
Parameters:
No. Parameter Parameter Value
1 Managed object
class
EFN324fport or ELN220port
2 Managed object
Instance
EFN324=<IP address>,port=<no.> or
ELN220=<IP address>,port=<no.>
3 Sequence number Alarm sequence number
4 Perceived severity Warning
5 Event time Time stamp from real time clock retrieved
through a SNTP server
6 Event type
CommunicationsAlarm
7 Probable cause
terminalProblem
Clearing Alarms
Linkup, ElnRestart