LBI-3890
8
23
Operational Software Fatal System Errors
ERROR NAME MESSAGE CODE DESCRIPTION
RADC_PITD_ERROR TRACKING 200 Personality tracking data error. Re-program the tracking data.
RADC_PIHW_ERROR PERSDATA 201 Personality hardware data error. Re-program the personality.
RADC_FREQ_ERROR FREQDATA 202 Personality frequency data error. Re-program the personality.
RADC_PITD_MALLOC_ERROR SOFTWARE 203 Personality tracking data malloc error. Re-program the tracking data.
RADC_PITD_CKSUM_ERROR SOFTWARE 204 Personality tracking data checksum error. Re-program the tracking data.
DACS_NO_LOCK NO LOCK 300 Synthesizer did not lock or became unlocked. Check the frequencies in the PC
programmer and re-program the radio personality.
DACS_MODEM_FATAL_ERROR SOFTWARE 301 Unable to correctly configure the modem for EDACS operation. Re-program
the personality.
DACS_RADC_FAILURE SOFTWARE 302 Power cycle the radio.
DACS_MODEM_RXOVR SOFTWARE 304 Hardware Modem overflow. Power cycle the radio.
DACS_MODEM_RXAVR SOFTWARE 305 Power cycle the radio.
CONV_RADC_ERROR SOFTWARE 400 Error calling RADC function. Power cycle the radio.
CONV_NOLOCK_ERROR NO LOCK 401 Synthesizer became unlocked. check the frequencies in the PC programmer
and re-program the radio personality.
CONV_PUT_UIMSG_ERROR SOFTWARE 402 UI message buffer not enabled. Power cycle the radio.
CONV_MODEM_RXOVR SOFTWARE 403 Conventional DIGV modem overflow.
CONV_MODEM_RXAVR SOFTWARE 404 Conventional DIGV modem underflow.
CONV_MODEM_FATAL_ERROR SOFTWARE 405 Unable to correctly configure the modem for conventional DIGV operation.
CONV_PERS_ERROR PERSDATA 407 Conventional personality error.
PI_NOPERS_ERROR PERSDATA 500 Personality data is not present. Program the personality.
PI_CRC_ERROR PERSDATA 501 Flash personality CRC did not match EEPROM. Re-program the personality.
PI_DESC_CRC_ERROR PERSDATA 502 Crucial personality data has incorrect CRC. Re-program the personality.
PI_MALLOC_ERROR SOFTWARE 503 Could not allocate memory to store crucial personality data.
UI_FATAL_DEVICE_ERROR PERSDATA 600 Input/Output device error.
UI_FATAL_SWTO_
MALLOC_ERROR
SOFTWARE 601 Software memory error.
UI_FATAL_SWTO_MAX_ERROR SOFTWARE 602 Software error, power cycle the radio.
UI_FATAL_WINDOW_MAX_
ERROR
SOFTWARE 603 Too many open windows.
UI_FATAL_WINDOW_MALLOC_
ERROR
SOFTWARE 604 Software memory error.
UI_FATAL_MESSAGE_INVPARM SOFTWARE 605 Invalid parameter to UI_PUT_MESSAGE(). software error, report how error
was encountered.
UI_FATAL_RI_MSGBUF_FULL SOFTWARE 606 UI Task message buffer full error. Software error, report how error was
encountered.
UI_FATAL_RISYS_MSGBUF_FULL SOFTWARE 607 Radio Interface System (EDACS/CONV) task message buffer full.
UI_FATAL_CI_MSGBUF_FULL SOFTWARE 608 CI Task message buffer full.
UI_FATAL_DEVICE_
NOTSUPPORTED
PERSDATA 609 I/O device type (from personality) not supported.
UI_FATAL_AUXIO_MALLOC_
ERROR
SOFTWARE 610 Software memory error.
UI_FATAL_NET_DEVICE_ERROR SOFTWARE 611 Network I/O device error
UI_FATAL_INVALID_CUID SOFTWARE 612 CU ID is invalid or CU not connected. Insure that CU ID is CUA and DUAL
is disabled in personality.
UI_FATAL_U110_MSGBUF_FULL SOFTWARE 613 No tone data is available in personality.
AEGIS_ADI_OVERFLOW SOFTWARE 801 ADI Transmit event not serviced in time and buffer has overflown.
AEGIS_RXBUF_MALLOC_ERROR SOFTWARE 802 No memory available.
AEGIS_KEYLOAD_MALLOC_
ERROR
SOFTWARE 803 No Keyloader table memory available.
AEGIS_KEYLOAD_ERROR SOFTWARE 804 General Keyload error has occurred.
AEGIS_DATAMEM_MALLOC_
ERROR
SOFTWARE 805 No memory is allocated for data.
AEGIS_KEYLOAD_NOTABL SOFTWARE 806 No key table was found in eeprom.