EasyManua.ls Logo

Ericsson ORION - Page 22

Ericsson ORION
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
L
BI-38993
Operational Software Fatal System Errors
ERROR NAME MESSAGE CODE DESCRIPTION
RADC_PITD_ERROR TRACKING 200 Personality tracking data error. Re-program the tracking data.
RADC_PIHW_ERROR PERSDATA 201 Personality hardware data error. Re-program the personality.
RADC_FREQ_ERROR FREQDATA 202 Personality frequency data error. Re-program the personality.
RADC_PITD_MALLOC_
ERROR
SOFTWARE 203 Personality tracking data malloc error. Re-program the tracking data.
RADC_PITD_CKSUM_
ERROR
SOFTWARE 204 Personality tracking data checksum error. Re-program the tracking data.
DACS_NO_LOCK NO LOCK 300 Synthesizer did not lock or became unlocked. Check the frequencies in the PC
programmer and re-program the radio personality.
DACS_MODEM_FATAL_
ERROR
SOFTWARE 301 Unable to correctly configure the modem for EDACS operation. Re-program the
personality.
DACS_RADC_FAILURE SOFTWARE 302 Power cycle the radio.
DACS_MODEM_RXOVR SOFTWARE 304 Hardware Modem overflow. Power cycle the radio.
DACS_MODEM_RXAVR SOFTWARE 305 Power cycle the radio.
CONV_RADC_ERROR SOFTWARE 400 Error calling RADC function. Power cycle the radio.
CONV_NOLOCK_ERROR NO LOCK 401 Synthesizer became unlocked. check the frequencies in the PC programmer and re-
program the radio personality.
CONV_PUT_UIMSG_
ERROR
SOFTWARE 402 UI message buffer not enabled. Power cycle the radio.
CONV_MODEM_RXOVR SOFTWARE 403 Conventional DIGV modem overflow.
CONV_MODEM_RXAVR SOFTWARE 404 Conventional DIGV modem underflow.
CONV_MODEM_FATAL_
ERROR
SOFTWARE 405 Unable to correctly configure the modem for conventional DIGV operation.
CONV_PERS_ERROR PERSDATA 407 Conventional personality error.
PI_NOPERS_ERROR PERSDATA 500 Personality data is not present. Program the personality.
PI_CRC_ERROR PERSDATA 501 Flash personality CRC did not match EEPROM. Re-program the personality.
PI_DESC_CRC_ERROR PERSDATA 502 Crucial personality data has incorrect CRC. Re-program the personality.
PI_MALLOC_ERROR SOFTWARE 503 Could not allocate memory to store crucial personality data.
UI_FATAL_DEVICE_
ERROR
PERSDATA 600 Input/Output device error.
UI_FATAL_SWTO_
MALLOC_ERROR
SOFTWARE 601 Software memory error.
UI_FATAL_SWTO_MAX_
ERROR
SOFTWARE 602 Software error, power cycle the radio.
UI_FATAL_WINDOW_MAX_
ERROR
SOFTWARE 603 Too many open windows.
UI_FATAL_WINDOW_
MALLOC_ERROR
SOFTWARE 604 Software memory error.
UI_FATAL_MESSAGE_
INVP_ARM
SOFTWARE 605 Invalid parameter to UI_PUT_MESSAGE(). software error, report how error was
encountered.
UI_FATAL_RI_MSGBUF_
FULL
SOFTWARE 606 UI Task message buffer full error. Software error, report how error was encountered.
UI_FATAL_RISYS_
MSGBUF_FULL
SOFTWARE 607 Radio Interface System (EDACS/CONV) task message buffer full.
UI_FATAL_CI_MSGBUF_
FULL
SOFTWARE 608 CI Task message buffer full.
UI_FATAL_DEVICE_
NOTSUPPORTED
PERSDATA 609 I/O device type (from personality) not supported.
UI_FATAL_AUXIO_
MALLOC_ERROR
SOFTWARE 610 Software memory error.
AEGIS_ADI_OVERFLOW SOFTWARE 801 ADI Transmit event not serviced in time and buffer has overflown.
22