Environmental Capabilities
Table 14
Environmental Parameters
Unit Value
Normal Condition Non-destruction
Temperature
C
-33 - +55 -40 - +70
Relative humidity % 5 - 100 5 - 100
Absolute humidity g/m
3
0.26 -40 0.26 - 40
Change of temperature
C/min
6 6
Rain temperature
C
5 5
Vibration sinus:
displacement mm 3
acceleration m/s
2
10
frequency Hz 2-9 9 - 200
Vibration random:
ASD m
2
/s
3
0.5 0.2
frequency Hz 2 - 200 200 - 500
Shock:
peak acc. m/s
2
100
1)
duration ms 11
Fauna none Not Appl. Not Appl.
1)
The requirements belong to the Safe function with one exemption:
performance of the RBS shall be veried as "no loss of calls".
EN/LZT 720 0024 R2A
2002-11-01
25 (34)