CelCulture CO2 Incubator ESCO
CCL-170B-8
CelCulture Control System
DECON Button & DECON LED
To activate 90oC moist heat decontamination procedure
During decontamination procedure, the yellow DECON LED will light up
MENU Button
When the main LCD shows normal display MENU button will activate the
menu options
Within the menu display MENU button will bring up the previous menu level
SET Button
Within the menu display SET button will confirm a selection or value
UP/DOWN Buttons
Within the menu display UP and DOWN buttons will scroll the display up and
down
When an input is required UP and DOWN buttons will increase and decrease
a value
MUTE Button & ALARM LED
MUTE button will mute the audible alarm for a period of time
The red ALARM LED will light up whenever an alarm condition is triggered
Question and Answer IconNeed help?

Do you have a question about the Esco CelCulture and is the answer not in the manual?

Esco CelCulture Specifications

General IconGeneral
BrandEsco
ModelCelCulture
CategoryAccessories
LanguageEnglish

Summary

CelCulture Control System Overview

DECON Button and DECON LED

Activates 90°C moist heat decontamination and indicates status with a yellow LED.

MENU Button Functionality

Used to activate menu options and navigate back to previous menu levels.

SET Button Functionality

Confirms a selection or value within the menu display.

UP/DOWN Buttons Functionality

Scrolls through menu options and adjusts values during input.

MUTE Button and ALARM LED

Mutes audible alarms and signals active alarm conditions with a red LED.

Incubator Indicators and Displays

HEAT LED Operation

Lights up when the heating process is activated.

INJECT LED Operation

Lights up when a gas injection process is activated.

oC/%RH Display Function

Displays the chamber temperature in °C and relative humidity in %RH.

%CO2/%O2 Display Function

Shows CO2 concentration level or O2 concentration level in the chamber.

Troubleshooting Common Issues

Unit Will Not Turn On

Addresses power failure causes and corrective actions for the unit not powering on.

CO2 Level Deviations

Troubleshoots issues where CO2 levels are below or above the set-point.

Temperature Set-Point Issues

Addresses causes and corrective actions when temperature deviates from the set-point.

Chamber Integrity and Air Leakage

Air Leakage Through Inner Door Gasket

Details checks for proper gasket installation and sealing to prevent air leakage.

Inner Door Opening and Access Ports

Addresses issues related to extended door openings and access port installation.

Humidity Level Management

Low Humidity Level Causes

Identifies causes for low humidity levels, primarily insufficient water in the humidity pan.

Cleaning and Decontamination Procedures

Cleaning Procedure Steps

Outlines steps for cleaning, including transferring samples, powering off, and disassembling parts.

Decontamination Process

Explains the 90°C moist heat decontamination routine for killing contaminants.