8.2 Menu Technical Settings (tEcH)
1.
2.
19
Press and hold > until the display shows tINE. Turn the dial
until display shows tEcH then press
< & > together to enter
Use the dial to choose between the below, then press > to
enter:-
dS: Delayed Start. Default is OFF. Use the dial to choose
between OFF (function disabled) or ON (heating on time is
delayed up to 40 minutes according to current room tempera-
ture)
tPI: TPI. Default is OFF. Use the dial to choose between OFF
(function disabled), 3CYC (each hour has 3 heating cycles,
recommended for oil boilers) or 6CYC (each hour has 6 heating
cycles, recommended for gas boilers)
SUG: Swing. Default is 1.0. Use the dial to choose between
0.5-2.0
AdJ: Temperature calibration. Default is 0. Use the dial to
choose between -3.0
o
C - 3.0
o
C
noP: Number of time and temperature events. Default is 6. Use
the dial to choose between 4 or 6 time and temperature events.
SEr: Landlord Service Interval. Default is OFF. See section 9
to amend