Overview
The SafeAir
TM
260-CO carbon monoxide (CO) detector is an accu-
rate and reliable means of alerting building occupants of potentially
dangerous levels of CO in the protected area. The internal electro-
chemical sensor communicates with a sophisticated on-board
microprocessor that accurately tracks CO levels over time.
This commercial-grade detection technology results in quick
response, reliable sensing, fast reset time, and superior false alarm
immunity. Its small size allows the 260-CO to blend inconspicu-
ously with any decor, and its smooth contoured design is compat-
ible with both residential and commercial environments.
Unaffected by normal indoor temperature variations, the 260-CO
automatically adjusts for environmental changes and operates
reliably under a wide variety of conditions. It also monitors its own
performance and compensates for sensitivity drift throughout the
course of its service life.
The 260-CO features the SafeTest™ functional test feature, which
facilitates testing with real CO gas. SafeTest meets the functional
test requirement in NFPA 720, 2009/2012 editions.
Like all CO detectors, the 260-CO has a limited service life. But
unlike most, which last only six years, the 260-CO’s advanced
sensor features a service life rated at 10 years. When it approach-
es this point, the 260-CO’s end-of-life timer automatically triggers
a warning that indicates the device must be serviced. This warning
annunciates at the detector, as well as at the control panel, and
optionally at a remote monitoring station.
An integrated temporal-4 sounder provides local signaling capability
for the 260-CO, and it easily interfaces with any intrusion or fire alarm
system by means of its output relay. Its low current draw results in
little additional demand on the system power supply.
Standard Features
10-year end-of-life signal
SafeTest
feature — functional test with spray of real CO gas
Advanced electro-chemical sensing technology
Wiring option activates sounders of all connected detectors
when any one of them goes into alarm
Deep housing with plenty of room for wiring
UL 2075 compliant
Transmits sensor end-of-life to the supervising panel and cen-
tral station if the system is monitored
CO sensitivity conforms to UL 2034 requirements
Built-in trouble/power supervision relay
Self-diagnostics keep the device operating optimally through-
out its service life
12 or 24VDC operation and 150mA Form C relay
Large SEMS terminals ease wiring installation 14 to 22 AWG
One-touch TEST/HUSH button simplifies local operation
Integrated 85 dBa temporal-4 sounder for local notification
On-board LED provides local alarm and trouble indication
Inconspicuous footprint and attractively contoured design
Adapter plate simplifies replacing ESL 240-COe detectors
12/24VDC
Carbon Monoxide
Detector with SafeTest
260-CO

Other manuals for ESL 260-CO

Question and Answer IconNeed help?

Do you have a question about the ESL 260-CO and is the answer not in the manual?

ESL 260-CO Specifications

General IconGeneral
BrandESL
Model260-CO
CategorySecurity Sensors
LanguageEnglish

Summary

Overview of Carbon Monoxide Detector

Standard Features of 260-CO Detector

Application of the 260-CO Detector

Recommended CO Detector Locations

Guidance on where to install CO detectors in residential and commercial settings.

Non-Recommended Installation Locations

Areas where CO detectors should not be installed to ensure proper function.

Operation of the 260-CO Detector

SafeTest Functional Test

Procedure for testing detector operation using CO test spray as per NFPA 720.

Distinct Temporal-Four Sounder Alarm

Description of the unique audible alarm pattern for CO detection.

Test/Hush Button Functionality

How to test the alarm and temporarily silence the sounder.

End of Sensor Life Indicator

How the detector signals that the sensor requires replacement.

Common Trouble Relay

Indication of trouble conditions via a relay output to the control panel.

Installation and Wiring

260-CO/240-COe Adapter Plate

Use of an adapter plate for replacing older CO detector models.

Wiring Configurations

Diagrams and explanations for single and multiple device wiring setups.

Tandem Interconnect

How to wire multiple detectors for synchronized alarm notification.

Specifications and Ordering Information

Product Specifications

Detailed technical specifications including voltage, current, and dimensions.

Ordering Information

List of product models, accessory part numbers, and contact information.