English
8-
TROUBLESHOOTING
• The pump does not stop:
- Water in the tank is empty.
Power the machine off, fill the tank, open the knob and switch the steamer on. The pump stops
running after the right water level in the boiler has been reached.
• No steam flows out the nozzle:
- The hole is clogged. Clean it from milk deposits by means of a thin needle.
- Water in the tank is empty:
When temperature is too high the high limit thermostats are activated. Power off the unit and wait at
least 30 minutes. Fill the tank, open the knob and power on the unit. The pump stops running after
the right water level in the boiler has been reached, dose the knob.
10