Questions and Answers

  • A
    Andrew WaltonSep 8, 2025
    How to fix flexible motor pump coupling swells in Et Industrial Equipment?
    • K
      Kristin MorrowSep 9, 2025
      If the flexible motor pump coupling swells, it's likely because the coupling has been soaked with oil. Replace the coupling and eliminate the oil leak; see Bulletin No. 100.
  • S
    Susan MckayAug 23, 2025
    What to do if Et Industrial Equipment guiding device drifts in one direction?
    • S
      Steven WheelerAug 23, 2025
      If the guiding device drifts in one direction, it could be due to the following causes: * There may be no or low oil in the Hymod. If this is the case, fill or top up according to Bulletin No. 100. * The pump inlet strainer could be clogged. If so, replace the Hymod; see Bulletin No. 100. * The oil pump shaft might be binding. Replace the pump and inspect the spider for wear or damage.
  • R
    Robert HarrisAug 25, 2025
    How to fix Et Industrial Equipment power unit operating hot?
    • S
      Shirley WashingtonAug 25, 2025
      If your Et Industrial Equipment power unit is operating hot, consider the following: * The motor cooling intakes might be clogged; clean them out. * The ambient temperature may be too high; reduce the ambient temperature, relocate the power unit to a cooler location, or cool the unit with a fan during operation. * The oil level might be low; top up as necessary.
  • N
    Nicholas CortezAug 26, 2025
    What to do if Et Industrial Equipment power unit will not start?
    • E
      Emily ThompsonAug 27, 2025
      If your Et Industrial Equipment power unit won't start, it could be due to several reasons: * There may be no power to the motor; connect the power. * There could be a heater trip; reset the heater and determine the cause. * The contactors may not close; replace the contactors and the coil. * A capacitor might be blown; replace the capacitor. * There might be an open or shorted motor winding; replace or repair the motor; see Bulletin No. 100.
  • D
    Daniel DeckerAug 27, 2025
    Why Et Industrial Equipment guiding device moves fast in one direction and slow in the other?
    • J
      Jeffrey GonzalezAug 28, 2025
      If the guiding device moves fast in one direction and slowly in the other, check these potential causes: * The S1 signal line could be cut or disconnected; replace or connect the line. * The S1 sensor orifice might be clogged; clean the orifice. * The blower filter may be clogged; clean or replace the filter.
  • M
    Michelle LeblancSep 22, 2025
    How to fix wrinkle into rewind or out of unwind on Et Industrial Equipment adapter base?
    • J
      Jeremy ButlerSep 22, 2025
      If there's a wrinkle into the rewind or out of the unwind on the adapter base, it could be due to: * Not enough span between the base idler (or roll) and the last process idler; the span must be lengthened; Contact your E+L representative for further information. * A misplaced edge sensor; relocate the sensor.
  • A
    Alicia MaloneSep 16, 2025
    What causes Et Industrial Equipment supporting knuckle of arcuate motion generator becomes loose?
    • C
      Chad NelsonSep 16, 2025
      If the supporting knuckle of the arcuate motion generator becomes loose and flops out of position, it's likely that the arcuate motion generator cable is broken. Repair the cable.
  • L
    Louis KingSep 18, 2025
    What causes Et Industrial Equipment idler bracket rocks?
    • C
      Cody GilmoreSep 18, 2025
      If the idler bracket rocks, it's likely that the bracket retaining bolt is loose. Tighten the bolt.
  • J
    Jeffrey KempSep 7, 2025
    What causes Et Industrial Equipment oil under power unit?
    • W
      Wayne BellSep 7, 2025
      Oil under the power unit suggests a leak from the Hymod, oil pump, or fittings. Replace the leaking Hymod or oil pump; see Bulletin No. 100.
  • S
    Steven BoydSep 4, 2025
    Why Et Industrial Equipment system generally unstable?
    • J
      Jennifer EllisSep 4, 2025
      If your Et Industrial Equipment system is generally unstable, it might be because the signal lines are too short or pinched. Install lines of the proper length.

Summary

SECTION I: DESCRIPTION AND OPERATION

ACTUATING DEVICES

Devices that act directly upon the web to control its position.

SENSING DEVICES

Devices that sense web location and send corrective signals to actuators.

SECTION II: INSTALLATION

HYDRAULIC AND PNEUMATIC INTERCONNECTIONS

Basic interconnection of power unit, sensor, and servo cylinder.

SECTION III: CHECKOUT

SECTION IV: OPERATING INSTRUCTIONS

SECTION V: MAINTENANCE AND REPAIR

SECTION VI: TROUBLESHOOTING

SECTION I: DESCRIPTION AND OPERATION

DESCRIPTION

Overview of the 400 Series WebAligner hydraulic power unit.

OPERATION

How the 400 Series WebAligner functions with edge detectors and servo-cylinders.

SECTION II: INSTALLATION

MOUNTING LOCATION

Guidelines for selecting an appropriate mounting location for the unit.

POWER CONNECTIONS

Instructions for electrical power connections, including motor rotation.

HYDRAULIC CONNECTION

Procedures for connecting hydraulic lines to the unit.

PNEUMATIC CONNECTIONS

Procedures for making pneumatic connections to the unit.

SECTION III: CHECKOUT

SECTION V: MAINTENANCE

HYDRAULIC OIL

Guidelines for checking and maintaining hydraulic oil levels.

BLOWER FILTER

Cleaning or replacing the blower filter.

SECTION VI: REPAIR

REPLACING THE HYMOD

Step-by-step guide for replacing the Hymod unit.

REPLACING THE MOTOR ASSEMBLY

Steps for removing and installing the motor assembly.

REPLACING MISCELLANEOUS PARTS

Guidance on replacing hoses, fittings, and other small parts.

SECTION I: DESCRIPTION AND OPERATION

DESCRIPTION

Overview of hydraulic servo cylinders used in guiding systems.

OPERATION

Explanation of how servo cylinders function, including force and speed.

SECTION II: INSTALLATION

MOUNTING

Guidelines for mounting servo cylinders on guiding devices.

HYDRAULIC CONNECTION

Procedures for connecting hydraulic lines to the servo cylinder.

SECTION III: CHECKOUT

SECTION V: MAINTENANCE AND REPAIR

SEAL REPLACEMENT

Instructions for replacing cylinder seal members.

SECTION I: DESCRIPTION AND OPERATION

DESCRIPTION

What pneumatic sensors are and their variations.

OPERATION

How pneumatic sensors receive air and function.

SECTION II: INSTALLATION

PNEUMATIC SENSORS

Parameters for installing pneumatic sensors.

POROUS SENSING OR THREE LEG SENSORS

Installation parameters for porous sensing or three-leg sensors.

SECTION III: CHECKOUT

CHECKING THE AIR JETS

Procedure to check air flow from sensor jets.

SECTION V: MAINTENANCE AND REPAIR

REPAIR

Information on sensor repair and replacement.

SECTION I: DESCRIPTION

DESCRIPTION AND OPERATION

Purpose and function of the Vernier Adjusting Bracket.

SECTION II: INSTALLATION

SECTION III: OPERATING INSTRUCTIONS

ADJUSTMENT DURING OPERATION

How to adjust the sensor position while the web is moving.

SECTION IV: MAINTENANCE AND REPAIR

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

SECTION 3: HAZARDS IDENTIFICATION

EMERGENCY OVERVIEW

Summary of hazards and immediate concerns for the product.

SECTION 4: FIRST AID MEASURES

SECTION 5: FIRE-FIGHTING MEASURES

SECTION 6: ACCIDENTAL RELEASE MEASURES

SECTION 8: EXPOSURE CONTROLS; PERSONAL PROTECTION

VENTILATION

Requirements for ventilation to maintain safe working environment.

PROTECTIVE GLOVES

Recommendations for using protective gloves.

SECTION 13: DISPOSAL CONSIDERATION

SECTION 15: REGULATORY INFORMATION

U.S. FEDERAL REGULATIONS

Compliance information for U.S. federal laws and regulations.

Et 400 Series Specifications

General IconGeneral
Input Voltage24 V DC
Protection ClassIP20
Power Supply24 V DC
MountingDIN Rail
SeriesET 400 Series
ApplicationIndustrial Automation