SOLENOID DRIVEN METERING PUMPS
WITH DIAPHRAGM
EN
OPERATING MANUAL
K PLUS - K CL PLUS - K CO PLUS
Self-venting version: KA PLUS
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Progettato da: Controllato da: Data:
Edizione
Foglio
/
A3 EMEC_Verticale
Massimo_F Massimo_F
31/05/2013
00
Toll. Gen.
±0.05
Peso Lordo: Peso Netto:
Materiale:
1 1
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Progettato da: Controllato da: Data:
Edizione
Foglio
/
A3 EMEC_Verticale
Massimo_F Massimo_F
31/05/2013
00
Toll. Gen.
±0.05
Peso Lordo: Peso Netto:
Materiale:
1 1
K CL PLUS
K CO PLUS
K PLUS
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Progettato da
Controllato da
Modificato da
Data
Edizione Foglio
/
A3emec
Massimo_F
16/11/2010
00
Toll. Gen.
0.05
Materiale:
1 1

Table of Contents

Questions and Answers

  • N
    nburkeAug 12, 2025
    How to fix eta Water Pump that does not start?
    • J
      Jill SmithAug 12, 2025
      If your eta Water Pump isn't starting, ensure that it is properly connected to the electrical network. If it is, check the fuse and replace it if necessary. If the issue persists, the main board might need replacement.
  • E
    Erica OchoaAug 21, 2025
    What to do if my eta K CL PLUS Water Pump does not feed but solenoid runs?
    • G
      Grant ForbesAug 21, 2025
      If your eta Water Pump isn't feeding water, but the solenoid is running, it could be due to several reasons. First, check the foot filter for any obstructions and clean it if necessary. It's also possible that the pump head or suction pipe is empty, in which case you'll need to prime the pump. Additionally, inspect the valves, pipes, and fittings for any issues. Finally, try opening the venting knob to release any trapped air, or consider using a self-venting pump head.
  • D
    dkellerAug 31, 2025
    What to do if eta K CL PLUS does not feed and solenoid does not run?
    • B
      Brian MoyerAug 31, 2025
      If your eta Water Pump isn't feeding water and the solenoid either doesn't run or runs slightly, the valves and/or ball valves might be blocked. Try cleaning them and then feed 2-3 liters of water to wash the valves and pump head. Another potential cause is an obstruction in the injection valve, in which case you should replace the valves.