Installation Guide
Copyright 2022 EtherWAN Systems, Inc. All Rights Reserved
EG97023 Layer 3 Hardened Managed Ethernet Switch | W70G-EG97023Q1
All power connection wiring should be made by a qualified electrician in
accordance with National Electrical Code, ANSI/NFPA 70 and Canadian Electrical
Code, Part I, CSA C22.1. An IEC certified or UL listed single-phase type circuit-
breaker, rated maximum 20A, shall be installed between mains circuit and
equipment.
Thumbscrews should be tightened with a tool after both initial installation
subsequent access to the panel.
Note: This equipment must use UL recognized Laser Class 1 optical transceiver.
This equipment is intended to be used in a restricted access location and be used
by a qualified person.
This equipment is not suitable for use in locations where children are likely to be
present.
Caution
This product relies on the building's installation for short-circuit (overcurrent)
protection and power disconnection. Ensure that the protective device is rated
MAX 20 A, 250 V and shall be easily accessible.
The performance levels of the field wiring terminals provided for power supply
connection:
a. Range of wire sizes: 10 - 18 AWG
b. Conductor material: copper wire only
c. Tightening torque(s): 14 In.-Lb
Manufacturer information:
ETHERWAN SYSTEMS, INC.
33F, No. 93, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City, 221 Taiwan
www.etherwan.com
If any items are missing or damaged, notify your EtherWAN representative.
If possible, save the carton and packing material in case you need to ship or
store the switch in the future. The full product manual can be downloaded
from:
www.etherwan.com