Ultraviolet radiation. Follow instructions. Avoid overexposure. As with
natural sunlight, overexposure can cause eye and skin injury and
allergic reactions. Repeated exposure may cause premature aging of the skin and skin cancer.
WEAR PROTECTIVE EYEWEAR; FAILURE TO MAY RESULT IN SEVERE BURNS OR
LONGTERM INJURY TO THE EYES. Medications or cosmetics may increase your sensitivity
to the ultraviolet radiation. Consult physician before using sunlamp if you are using medications
or have a history of skin problems or believe yourself especially sensitive to sunlight. If you do
not tan in the sun, you are unlikely to tan from the use of this product. Children, the elderly, or
fair skinned people who always burn easily and either never tan or tan minimally should not use
this equipment.
To use, lie down under canopy and pull down as far as adjustment will allow. Do not use without
clear plastic panel and wire grill in place. Untanned persons should not tan on consecutive days
during their first week of tanning. Never tan more than once a day. Tanning normally appears after
the first few sessions and maximizes after approximately four weeks. Tan once or twice per week
thereafter to maintain appearance. Persons already having a base tan may begin at advanced
levels corresponding to the extent of their base tan.
Skin Type:
I Sensitive Skin (Burns easily and severely and does not tan.)
II Light Skin (Burns easily and severely and tans minimally.)
III Normal Skin (Burns moderately and tans average.)
IV Dark Skin (Burns minimally, tans easily and above average.)
New lamps emit approximately 10% more ultraviolet radiation during the first 50 hours of
operation. Recommended tanning times should therefore be reduced by approximately 10%
during that period.
WARNING
: • Read these instructions before using this sunlamp product. • All persons in the
room should wear protective eyewear when lamps are on. Recommended eyewear: provided
eyeshields or equivalent eyewear as defined under 21 CFR 1040.20. Other types of eyewear
may not provide adequate protection. Failure to use protective eyewear may result in severe
burns or other eye injury. If discomfort develops, discontinue use and consult a physician.
THE FOLLOWING LAMPS HAVE BEEN CERTIFIED FOR USE IN THE 16RS:
DARK TAN™ Wolff® Model DT71-T12-100W BI-PIN
Triple Twister Model F71T12/BL/HO/BP
THIS EQUIPMENT MUST BE EARTH GROUNDED.
This product is in conformity with performance standards for sun lamp
products under 21 CFR PART 1040.20 and ANSI/UL Standard 482.
88465
DISCONNECT POWER CORD BEFORE ATTEMPTING TO CLEAN, RELAMP,
OR ENGAGE IN THE MAINTENANCE OF THIS PRODUCT.
WARNING
Wear protective eyewear.
Failure to may result in severe burns or longterm injury to the eyes.
DANGER
Shock hazard.
Disconnect power before servicing or removing any protec-
tive covers.
Do not operate this device near water or while you are wet.
DANGER
Some medications may increase your sensitivity to ultraviolet light. It
is recommended that you consult a physician before using this
sunbed if taking any medication or if you suspect that your skin might
be especially sensitive to sunlight.
CAUTION
Air from the room is used to cool the sunbed. Maximum ambient room
temperature should be 80°F. Place your sunbed no closer than 6” from
any wall. Make sure nothing obstructs the airflow into the sunbed’s
endcaps or out of the fan openings. A poorly ventilated room may
cause the unit to become hot and cause discomfort to the user.
Unpacking and Inspection
Your sunbed comes in two cardboard cartons. Pull back the plastic
sheet and, with a helper, grasp the bench and pull it from the carton
bottom, leaving the plastic wrap and the carton packaging. Do not try
to lift the unit with the plastic still on as it may slip. Do the same with
the canopy.
The canopy box contains the canopy and a pair of gas springs. The
bench box contains the bench, assembly hardware and stand legs.
Inspect the items and make sure they are free from any visible damage.
Report the extent of any damage to the transportation company.
Electrical Requirements
Your sunbed operates from a 120V AC source. You should have a
NEMA 5-15R electrical outlet (below), on a dedicated circuit capable
of providing 15 Amp service, installed in the room in which you will
use the unit. We recommend installation by a professional electrician.
The outlet must be earth grounded.
15 AMP NEMA #5-15R
RECEPTACLE
29008-01A
Allen-head Bolt 5/16” x 1”
Quantity 2
5/16” Metal Washer
Quantity 2
Bushing
Quantity 2
Allen-head Bolt 5/16” x 1 1/2”
Quantity 2
Nylon Washer
Quantity 2
Hinge Brackets
(1) left, (1) right
Hex (Allen) Wrench
Quantity 1
Safety Goggles
Quantity 1
Hardware Inventory (These items and a small pillow)
RECOMMENDED EXPOSURE TIMES IN MINUTES
Level 1/Week 1
Level 2 Level 3 Level 4 Level 5
Skin Type: 1st-3rd Sessions
I Sensitive NOT RECOMMENDED FOR TANNING
II Light 4 8 12 16 20
III Normal 6 10 15 20 20
IV Dark 8 12 16 20 20
MAXIMUM EXPOSURE TIME IS 20 MINUTES
DANGER
Question and Answer IconNeed help?

Do you have a question about the ETS Sunquest 16RS and is the answer not in the manual?

Summary

Safety Warnings and Precautions

Shock Hazard and Electrical Safety

Disconnect power before servicing; avoid water during operation.

Ultraviolet Radiation Sensitivity

Consult physician if sensitive to UV light or taking medication.

Eye Protection Requirement

Wear protective eyewear to prevent severe burns or long-term eye injury.

Room Ventilation and Temperature

Ensure adequate airflow for cooling; maximum ambient room temp 80°F.

Electrical Requirements

Outlet and Circuit Specifications

Requires 120V AC, 15 Amp dedicated circuit with NEMA 5-15R grounded outlet.

Unpacking and Inspection

Hardware Inventory

List of included items for assembly: bolts, washers, wrench, goggles.

Assembly Procedures

Bench Assembly Steps

Attaching stand legs, hinge brackets, and securing bolts for the bench.

Canopy Attachment and Gas Springs

Connecting canopy, attaching gas springs, and securing power cord.

Final Power Connection

Connecting the three-prong power cord to a dedicated outlet.

Using Your Sunbed

Skin Type and Exposure Guidelines

Table of recommended tanning times based on skin type and session number.

Sunbed Operation Controls

Using the timer, timer button, and stop button for tanning sessions.

Care and Maintenance

Cleaning Procedures

Instructions for cleaning after use and thorough periodic cleaning.

Mechanical and Acrylic Inspection

Checking fasteners, gas springs, power cord, and acrylic condition.

Removing and Replacing Parts

Procedures for removing bench acrylic shield and canopy grill.

Replacing Lamps

Lamp Replacement Procedure

Steps for removing and reinstalling lamps by turning a quarter turn.

Certified Lamp Models

List of certified lamps for the SunQuest 16RS model.

Troubleshooting

Sunbed Not Tanning Issues

Solutions for sunbed not tanning: cleaning, lamp replacement, acrylic.

Lamp and Timer Display Problems

Troubleshooting for lamps not lighting or blank timer display.

Canopy Not Staying Up

Fixes for canopy not holding position, including gas springs.

Warranty Information

18 Month Bronze Medal Warranty

Details on parts warranty, exclusions, and disclaimers.

Obtaining Warranty Service

Contact information and requirements for warranty service.

ETS Sunquest 16RS Specifications

General IconGeneral
BrandETS
ModelSunquest 16RS
CategoryTanning Beds
LanguageEnglish

Related product manuals