When Measuring
Issue Cause Solution
Abnormal measurement
results:
• Too high
• Too low
• Huge dierence
between two recent
measurements
• Incorrect posture.
Step onto the scale barefoot and
stand still.
• Device is placed on
soft carpeting or
uneven surface.
Place the device on a hard and flat
surface.
LED display does not turn
on after stepping onto the
scale.
• Batteries not
installed.
• Install three new batteries.
• Worn batteries.
• Replace all three batteries at the
same time.
Scale does not proceed to
analyse body composition.
• Taking
a measurement while
wearing shoes or
socks.
• Stand barefoot on the scale and
keep feet in full contact with
the electrodes when taking a
measurement.
Specifications
Product Model T9146
Power Source 4.5 V (3 × AAA batteries)
LED Display 67 × 29 mm / 2.6 × 1.2 in
Measurement Unitse Pound / Kilogram
Unit Increments 0.1 lb / 0.1 kg
Body Fat Unit Increments 0.1 %
Body Water Unit Increments 0.1 %
Muscle Mass Unit Increments 0.1 %
Measurement Range 11-397 lb / 5-180 kg
Working Environment
Temperature: 5 - 40 °C
Humidity: 20 - 90% RH
Storage Environment
Temperature: -20 - 50 °C
Humidity: <= 90% RH
Operating Frequency Range 2402 - 2480 MHz
Radio-Frequency Power 4 dBm
Dimension 280 × 280 × 23 mm / 11.0 × 11.0 × 0.9 in
Net Weight 3.31 lb / 1. 5 kg
Weight-Only Measurement
This scale can also be used as a conventional weight-reading scale. You can
simply step on the scale to measure your current weight without opening the
EufyLife app.
Maintenance
Regularly clean the scale with a dry or slightly dampened soft cloth.
- Do not wash the scale with water or immerse it in water.
- Never use detergents to clean the scale as this may cause it
to malfunction or discolor.
Troubleshooting
Error Message
Error Display Description Solution
Overload. The device will power o. Stop using this scale for measurement.
Low battery. The device will
power o.
Replace all three batteries at the same
time.
Measurement failure.
• Step barefoot and keep full contact
with the electrodes.
• Stand still until the measurement on
the LED display locks.