Important Safety Instructions

Electrical Safety and Cord Handling

Ensure electrical voltage and frequency match appliance rating plate. Check wiring capacity, earthing, and dedicated outlet for safety. Connect plug securely and ensure socket suitability to prevent shock/fire. Avoid using extension cords or adaptors. Handle power cord carefully to prevent damage and risk of shock/fire. Replace damaged power cords only via authorised service. Do not unplug during operation to avoid sparks and fire risk. Disconnect power when not in use or for maintenance, grip plug not cord.

Important Safety Instructions (Cont.)

Usage Conditions and Restrictions

Ensure appliance complies with regulations and is used only for domestic air conditioning. Use common sense, avoid alterations, supervise children and those with limited capabilities. Use air filter, avoid direct cold air, do not block openings or insert objects.

Important Safety Instructions (Cont.)

Smoke, Refrigerant, and Repair Safety

Disconnect if smoke/burning smell occurs; ensure ventilation for refrigerant safety. Check refrigerant system for leaks. Always disconnect power before cleaning or maintenance. Use only authorised centres for repair; do not use faulty units.

Product Overview

Window Air Conditioner Components

Overview of the window air conditioner's external components and labels like grilles, covers, and panel.

Control Panel and Remote Control

Illustration and identification of the unit's control panel buttons and the remote control.

Product Overview (Cont.)

Scope of Delivery and Inclusions

List and illustration of included accessories like drainage parts, batteries, and main unit/remote references.

Getting Started

Unpacking and Initial Setup

Unpack carefully, keep packaging, inspect cord for damage, read manual, and set up remote control and holder.

Installation

Electrical Specifications and Safety

Ensure wiring complies with regulations, outlet is grounded, use correct power supply as per rating plate, and use a dedicated circuit breaker.

Installation Safety Precautions

Ensure unit is off and unplugged before starting installation. Ensure proper means for mains disconnection are incorporated into fixed wiring.

Installation (Cont.)

Location and Clearance Requirements

Choose a solid wall location away from heat/flammable gas and obstacles. Maintain 100mm clearance to combustibles and ensure unobstructed airflow.

Drainage and Installation Details

Position unit for drainage and ensure rear side is lower. Wall thickness considerations for installation.

Installation (Cont.)

Unit Removal and Preparation

Steps to remove panels, chassis, and slide the main unit out of its cabinet.

Bottom Condensation Drainage

Attach drainage tray to underside and block rear hole for bottom drainage method.

Installation (Cont.)

Back Condensation Drainage

Secure sealing ring into back drainage hole and block bottom hole for back drainage method.

Unit Installation and Reassembly

Secure cabinet on shelf, support unit, slide back into cabinet, and reassemble front panel, filter, and grille.

Operating Instructions

Control Panel Operation

Explains the function and operation of each button on the unit's control panel for ON/OFF, SLEEP, AUTO SWING, TIMER, FAN SPEED, and MODE.

Timer and Temperature Settings

How to set ON/OFF timers, adjust fan speed, temperature, and switch between Celsius/Fahrenheit.

Operating Instructions (Cont.)

Control Panel Symbols

Explains the meaning of symbols displayed on the control panel for fan speed, display, timer, sleep, and mode.

Remote Control Usage

Best practices for using the remote control effectively, including sensor alignment, battery checks, environmental factors, and storage.

FAQs and Troubleshooting Guide

Maintenance and Repair Precautions

Switch off and disconnect power before maintenance; use qualified technicians for repairs. Do not attempt self-repair.

Common Issue Resolution

Guide to diagnose and resolve common air conditioner operational problems like not working, poor cooling, noise, and odor.

Other Useful Information

Cleaning Safety and Procedures

Safety precautions for cleaning, including disconnecting power, water temperature limits, and detergent types. Instructions for cleaning the exterior and air filter.

Air Filter Maintenance

Step-by-step guide on how to wash and maintain the air filter for optimal performance. Information on replacement filters.

Other Useful Information (Cont.)

End of Season Maintenance

Steps for end-of-season maintenance, including drying, cleaning fins, and removing remote batteries for storage.

Battery Management and Precautions

Instructions for replacing remote control batteries and safety guidelines for battery usage, charging, disposal, and handling leaks.

Other Useful Information (Cont.)

Service, Repair, and Spare Parts

Information on obtaining service, repair, and a list of available spare parts for the air conditioner.

Disposal and Installer Information

Guidelines for responsible disposal of the appliance and fields for recording installer details for future reference.

Other Useful Information (Cont.)

Technical Specifications

Detailed technical specifications of the air conditioner, including capacity, current, power input, noise, dimensions, and operating conditions.

Product Support and Warranty

Warranty Returns Process

Instructions for returning the product for warranty claims, emphasizing inclusion of all accessories.

Troubleshooting and Contact Information

Guidance on contacting After Sales Support for product issues and advice.

Overview

This document describes the EUROMATIC 2.6kW / 2.4kW Reverse Cycle Window / Wall Air Conditioner, Model EUR-9000WAC. It serves as an instruction manual covering installation, operation, and maintenance.

Function Description

The EUROMATIC EUR-9000WAC is a reverse cycle window/wall air conditioner designed for air conditioning domestic environments. It provides both cooling and heating functions, making it suitable for year-round use. The unit can be operated via a control panel on the front or a supplied remote control. Key functions include temperature setting, fan speed adjustment, timer operation, and a sleep mode for comfortable overnight use. The reverse cycle capability allows it to efficiently cool in warm weather and heat in cold weather.

Important Technical Specifications

The EUR-9000WAC model offers the following technical specifications:

  • Capacity:
    • Cooling: 2600 W
    • Heating: 2400 W
  • Current:
    • Cooling: 3.4 A (rated), 7.1 A (max.)
    • Heating: 3.2 A (rated), 4.9 A (max.)
  • Power Input:
    • Cooling: 790 W
    • Heating: 730 W
  • Rated Power Input (AS/NZS 60335):
    • Cooling: 1400 W
    • Heating: 1000 W
  • Maximum Pressure:
    • Discharge: 4.5 MPa
    • Suction: 1.5 MPa
  • Noise:
    • Inside: 47–51 dB(A)
    • Outside: 55–59 dB(A)
  • Indoor Air Volume: 430 m³/h
  • Weight: 33 kg
  • Rated Voltage: 220–240 V~
  • Rated Frequency: 50 Hz
  • Refrigerant: R410A
  • Refrigerant Quantity: 720 g
  • Waterproof Protection (Outdoor Part): IPX4
  • Dimensions (mm): W600 x D560 x H380
  • Operation Temperature: 18–31°C
  • Room Size Suitability: 10–18 m²

Usage Features

The air conditioner offers several features for user convenience and comfort:

  • Control Options: Can be operated directly from the front control panel or using the supplied remote control.
  • ON/OFF: Simple button press to turn the unit on or off.
  • SLEEP Function: Activates a mode that automatically controls temperature for comfortable sleep, switching off after 10 hours.
  • AUTO SWING: Starts or stops the left/right airflow swing. Vertical airflow can be manually adjusted using deflectors.
  • TIMER Function: Allows setting an ON or OFF timer for up to 24 hours. The LED displays remaining time and then the set temperature. The timer can be cancelled by pressing the TIMER button while the remaining time is displayed.
  • FAN SPEED Selection: Users can choose between Auto, High, Medium, and Low fan speeds.
  • Temperature Setting: UP/DOWN buttons allow increasing or decreasing the temperature or time by 1 unit within a range of 16°C–31°C.
  • Temperature Scale Change: Holding both UP/DOWN buttons simultaneously for more than 3 seconds switches the temperature display between Celsius (°C) and Fahrenheit (°F).
  • Operation Modes: Users can cycle through Cooling, Fan Only, and Heating modes using the MODE button.
  • Remote Control Holder: A wall-mounted holder is supplied for convenient storage of the remote control.
  • Drainage Options: The unit supports both bottom drainage (using a supplied drain tray and stopper for the back hole) and back drainage (using a sealing ring and drainage mouth, with a stopper for the bottom hole).

Maintenance Features

Regular maintenance is crucial for optimal performance and longevity of the air conditioner.

  • Cleaning the Air Conditioner:
    • The front cover should be wiped with a soft, dry cloth regularly. For excessive dirt, a soft cloth dampened with warm water (max 40°C) and mild detergent can be used, followed by thorough drying. Harsh solvents or detergents should be avoided.
    • Always switch off the unit and disconnect it from the mains power supply before cleaning.
  • Cleaning the Air Filter:
    • The air filter should be washed at least once a month to prevent dust accumulation and maintain cooling capacity.
    • To clean, open the air intake grille, pull out the filter, wash it under running water (or with water and mild detergent if needed), rinse with clean water, and air dry in the shade. Do not dry in direct sunshine.
    • The unit must not be operated without the filters reinstalled.
    • Replacement air filters are available from the after-sales support centre.
  • End of Season Maintenance:
    • On a dry day, operate the fan (LOW, MID, or HIGH speed) for half a day to ensure the unit's interior is completely dry.
    • Switch off the unit and disconnect it from the wall socket.
    • Clean and replace the air filter.
    • Clean the condenser fins (back of the unit) and evaporator (front of the unit) using a soft brush or vacuum cleaner attachment. Handle with care to avoid damaging the fins.
    • Remove batteries from the remote control if the appliance will not be used for a prolonged period.
  • Battery Replacement (Remote Control):
    • When batteries are flat or before long-term storage, slide open the battery cover, remove old batteries, and insert two fresh AAA (1.5V) batteries, observing polarity markings.
    • Battery Precautions: Use only fresh batteries of the required size and type. Do not mix old and new, or different types. Keep batteries away from children. Do not charge, heat, burn, open, or short-circuit batteries. Dispose of batteries properly according to local regulations; do not burn or bury them. In case of battery acid leakage, avoid contact with skin/eyes/mucous membranes; rinse affected areas immediately with clean water and seek medical attention.
  • Servicing and Repair:
    • Do not attempt to repair or modify the appliance yourself.
    • Any repairs must be carried out by an authorised service centre or qualified technician.
    • In case of technical fault, do not use the appliance; contact a qualified service technician or the after-sales support centre.
    • If smoke or a burning smell is detected, immediately disconnect the unit and contact after-sales support.
  • Responsible Disposal:
    • Packaging materials are recyclable and should be disposed of responsibly.
    • At the end of its working life, the appliance should not be disposed of with household rubbish. Electrical and electronic products contain substances that can be harmful to the environment and human health. Dispose of it appropriately for recycling and refrigerant recovery according to local regulations. Contact local authorities for recycling facilities.

Euromatic EUR-9000WAC Specifications

General IconGeneral
BrandEuromatic
ModelEUR-9000WAC
CategoryAir Conditioner
LanguageEnglish