EVA Logik ZW97 - Configuration and Advanced Features; Z-Wave Configuration Parameters; Association Group Support

EVA Logik ZW97
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
ZW97 protocol Endpoint 1
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
ZW97 protocol Endpoint 2
Full Command Class Node Info
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
Z-Wave Configuration Parameters
1:
Status LED Configuration
Paramter No: 1(0x01) Size:1 Byte Value: 00(default) outlet on,led on.
Value: 01 outlet on,led off.
Value: 02 led no work.
2:
Count Down Configuration(Turn off the output by time
Paramter No: 2(0x02) Size:2 Byte Value: xx xx Turn off left outlet
Turn off Endpoint1 outlet
Value Scope :0----36000S (default:00 00 no timer)
Paramter No: 3(0x03) Size:2 Byte Value: xx xx Turn off right outlet
Turn off Endpoint2 outlet
Value Scope :0----36000S (default:00 00 no timer)
You may use the below configuration parameters to change settings of the corresponding functionality.
Support for Association Groups
ZW97 supports 3 association groups. A maximum of 5 node ID’s (nonmulti-channel devices) can be assigned to these association groups.

Other manuals for EVA Logik ZW97