6540372 PUMP SE 044A 3 X 220V 50 HZ 6540381 PUMP SE 044A 3 X 690V 60 HZ
6540369 PUMP SE 044A 3 X 380-420V 50 HZ 6540371 PUMP SE 044A 3 X 230V 60 HZ
6541600 PUMP SE 044A 3 X 690V 50 HZ 6540370 PUMP SE 044A 3 X 460V 60 HZ
mechanical seal.
2. Start-up procedure
Clean the holding tank and pipework from any foreign objects. Fill the holding tank to the lling level before
starting the pump. Follow the operation of the pump and check that it starts and stops as per in electric
drawings.
3. Operation
During regular inspections check:
• that there are not alarms on
• that the pump does not make an unusual noise when running
• that the “running hours” meters of alternately running pumps show roughly the same reading
4. Maintenance
Evac SE 044A pump is specially designed to run together with Evac -ejector in heavy duty sewage conditions
with minimal maintenance. The pump is equipped with Vortex impeller with no clearance adjustment, high
quality mechanical seal and electric motor bearings for long life operation.
Once a year
Start pump manually and check that:
there are not leakages
pump is running smoothly
the ejector generates vacuum normally
alarms, valves etc. operate normally
At 10 000 running hours (or every ve years)
Dismantle the pump and:
clean pump housing
change mechanical seal (5451310)
change O-ring (5451330)
change electric motor bearings
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
1. Installation
Install the pump to the base and ensure that no load is transferred
to the pump from the pipework. Use suitable spacers between the
pump and the base when necessary. Follow the instructions of the
manufacturer of motor and make sure that cooling air is provided
for the motor.
Adjust pipework on the suction and pressure side so that the anges
t easily together. Make sure that xing of bolts will not cause any
load to the pump body. Connect the cable to the control panel as
shown in the electrical diagram. Check direction of rotation to be
clockwice by shortly starting the pump.
! NOTE: Do not run the pump dry for more than just a few seconds, because longer dry running will damage the
Question and Answer IconNeed help?

Do you have a question about the Evac 6540372 and is the answer not in the manual?

Summary

Installation, Operation and Maintenance Instructions

1. Installation

Install the pump to the base, ensure no load transfer from pipework. Adjust pipework and check rotation.

2. Start-up procedure

Clean holding tank and pipework. Fill tank to level and check pump operation.

3. Operation

During regular inspections, check for alarms, unusual noise, and running hours.

4. Maintenance

Evac SE 044A pump requires minimal maintenance. Regular checks and periodic overhauls.

5. Change of mechanical seal

5.1 Removal of impeller

Unscrew impeller locking screw, protect thread, use puller carefully. Change screw each time.

5.2 Removal of seal

Loosen retaining ring screw. Pull retaining ring, seal spring, and rotating seal ring away carefully.

5.3 Dismantling the rear wall and stationary seal ring

Undo motor flange bolts, pull rear wall. Remove stationary seal ring if damaged.

5.4 Assembly of stationary seal ring

Clean rear wall, lubricate O-ring. Assemble carefully, align groove, use assembly tool PUR 012.

5.5 Assembly of rotating seal ring

Lubricate O-ring/surfaces. Protect shaft keyway. Press rotating seal ring with spring/retaining ring using PUR 035.

5.6 Assembly of rotating seal ring without assembly tool PUR 035

Assembly without a special tool is not recommended but possible if spring compression is correct.

5.7 Installation of the impeller

Install shaft key and impeller. Secure with locking screw (P/N 5451350). Change screw each time.