3 Flash: COMPRESSOR START ERROR
Cause:
Stopping and starting too quickly (not giving the system time to equalize).
Electronic box issue.
Faulty compressor.
Disconnect power for ten minutes, then re-start, if problem persists, contact Evakool.
4 Flash: MINIMUM MOTOR SPEED ERROR
Cause:
If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm.
Very high ambient temperatures (move to a cooler area).
Blocked or dirty condenser (clean and re-test).
Fan not working (contact Evakool).
5 Flash: OVER TEMPERATURE ERROR
Cause:
Ambient temperature too high (move to a cooler area).
Blocked or dirty condenser (clean and re-test).
Fan not working (contact Evakool).