3 Flash: COMPRESSOR START ERROR
Cause:
• Stopping and starting too quickly (not giving the system time to equalize).
• Electronic box issue.
• Faulty compressor.
• Disconnect power for ten minutes, then re-start, if problem persists, contact Evakool.
4 Flash: MINIMUM MOTOR SPEED ERROR
Cause:
• If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm.
• Very high ambient temperatures (move to a cooler area).
• Blocked or dirty condenser (clean and re-test).
• Fan not working (contact Evakool).
5 Flash: OVER TEMPERATURE ERROR
Cause:
• Ambient temperature too high (move to a cooler area).
• Blocked or dirty condenser (clean and re-test).
• Fan not working (contact Evakool).