EasyManua.ls Logo

EvaKool MAXI TRAC MT-45 - Page 12

EvaKool MAXI TRAC MT-45
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Compressor Evakool CK25
Displacement cm
3
2.5
Application LBP
Rotation RPM 2000 2500 3000 3500
Capacity W 40 50 60 70
Input Power W 36 44 50 60
Operating Current A 3 3.7 4.3 5
COP W/W 1.1 1.14 1.15 1.16
Cooling Static or Fan Cooling
Lubricant Polyester
Weight of Compressor 3.1
Weight of Controller 0.16
Motor Type BLDCM
Refrigerant R134a
Throttling Device Capillary
Power Supply V.DC 12/24
Test Conditions
Evaporating Temp -23°C Suction Temp 32.2°C
Condensing Temp 54.4°C Sub Cooling Temp 32.2°C
Ambient Temp 32.2°C Test Voltage 12VDC
for 24V applications the current must be halved
Cable Length Specification
The DC cables must have a suitable cross-section for their length (measured from the
battery to the unit), according to this table:
Cable Thickness 12V Max Cable Length 24V Max Cable Length
(mm2) AWG (m) () (m) ()
2.5 14 2.5 8 5 16
4 12 4 13 8 26
6 10 6 20 12 39
10 8 10 33 20 66
12