12
ENGLISH
DESCRIPTION OF CYCLES
POSITIVE CHILLING WITH CORE PROBE
SOFT - Chapetr 9.2.4
► Room temp. setpoint.: 0°C
► Core probe temp. setpoint.: 3°C
+
SORING CYCLE
► Setpoint Temp. room: 2°C
HARD - Chapetr 9.2.5
a) 1st phase
► Room temp. setpoint.: -20°C
► Core probe temp. setpoint.: 15°C
a) 2nd phase
► Room temp. setpoint.: 0°C
► Core probe temp. setpoint.: 3°C
+
STORAGE CYCLE
► Room temp. setpoint.: 2°C
POSITIVE TIME-BASED CHILLING
SOFT - Chapetr 9.2.6
100% of time Soft chilling
► Room temp. setpoint.: 0°C
+
STORAGE CYCLE
► Room temp. setpoint.: 2°C
HARD - Chapetr 9.2.7
60% of time Hard chilling
► Room temp. setpoint.: -20°C
40% of time Soft chilling
► Room temp. setpoint.: 0°C
+
STORAGE CYCLE
► Room temp. setpoint.: 2°C
FREEZING WITH CORE PROBE
SOFT - Chapetr 9.2.9
a) 1st phase
► Room temp. setpoint.: 0°C
► Core probe temp. setpoint.: +3°C
a) 2nd phase
► Room temp. setpoint.: -40°C
► Core probe temp. setpoint.: -18°C
+
STORAGE CYCLE
► Room temp setpoint: -20°C
HARD - Chapetr 9.2.8
► Room temp setpoint: -40°C
► Core probe temp. setpoint: -18°C
+
STORAGE CYCLE
► Room temp. setpoint.: -20°C
TIME-BASED FREEZING
SOFT - Chapetr 9.2.11
60% of time Soft chilling
► Room temp. setpoint.: 0°C
40% of time Hard chilling
► Room temp. setpoint.: -40°C
+
STORAGE CYCLE
► Room temp. setpoint.: -20°C
HARD - Chapetr 9.2.10
100% of time Hard chilling
► Room temp. setpoint.: -40°C
+
STORAGE CYCLE
► Room temp. setpoint.: -20°C