EasyManua.ls Logo

Everlasting BASIC TRAY - Page 14

Everlasting BASIC TRAY
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
ENGLISH
9.2.4 POSITIVE SOFT CHILLING with core probe and subsequent storage
The time-based chilling and storage cycle consists in two phases:
1st phase: Soft chilling cycle (Room temp. setpoint 0°C; Core probe temp. setpoint 3°C)
2nd phase: Storage (Room temp. setpoint 2°C)
- Make sure the blast chiller is in “
ON/STAND-BY
” mode, that the keyboard is not locked (chapter 11) and
that no procedures are being carried out.
Press and release the key: the icon starts ashing
The display shows the room’s temperature setpoint.
It is possible to use the keys to modify this value.
Press and release the key within 20
seconds:
and icons remain on, and a one-
minute test is carried out, to make sure the core
probe has been correctly inserted:
If the test has a positive outcome, the chilling
cycle with core probe does not stop.
If the test has a negative outcome (e.g. core
probe not inserted), the acoustic buzzer warns
us 3 times (each 10 seconds) that the core probe
has not been inserted. In this case there is no
need to press any keys, after 30 seconds a time-
based cycle automatically begins.
During the chilling cycle a temperature, the display shows the temperature detected by the
core probe, and the
icon is on.
It is possible to display the room’s temperature in any moment, pressing and releasing the
key.
To restore the standard display mode, press and release the same key or do not operate for
15 seconds.
Once the chilling cycle has been carried out, the blast chiller automatically switches to a
storage cycle.
During the storage, the display shows the temperature detected by the room probe and the
icon is on.
To stop any cycle, press the key.
NB: If the required temperature is not reached within the scheduled time (positive chilling: 90 min,
freezing: 240 min), a recursive beep is issued as warning.
The blast chiller keeps chilling / freezing until reaching the scheduled temperature. Failure to reach
the temperature within the scheduled time may take place when introducing products which are
bigger in size or weight compared with the standard ones or products with higher temperature of the
maximum allowed.