1
ENGLISH
Thank you for choosing this product.
Please read the warnings contained in this manual carefully, as they provide important information
regarding safe operation and maintenance.
Make sure to keep this manual for any future reference by the various operators.
In some parts of the manual, the
symbol appears, indicating an important warning that must
be observed for safety purposes.
CHAPTER 1 BOUNDARY CHARACTERISTICS OF OPERATION
The blast chiller has been designed and built to operate in optimal conditions at temperatures of
up to +43°C, with adequate air circulation. In places with characteristics that are different from the
requirements, the stated performance cannot be guaranteed.
The supply voltage must be 230V +/- 10% 50Hz as standard, or as indicated on the EC label.
The following table shows the cooling and/or freezing capacity in kg.
Model Blast chilling +90°C / +3°C Rapid freezing +90°C / -18°C
BASIC TRAY MINI 7 Kg. 5 Kg.
BASIC TRAY 04 10 Kg. 7 Kg.
BASIC TRAY 05 16 Kg. 12 Kg.
BASIC TRAY 07 24 Kg. 16 Kg.
BASIC TRAY 10 33 Kg. 23 Kg.
BASIC TRAY 15 50 Kg. 35 Kg.
N.B.: the times and quantities in kg above are valid for products with a maximum thickness of 4 cm.
Maximum time:
Positive chilling: 90 min, Freezing: 240 min
The blast chiller complies with the European directives as described in detail in the Annex “EC Declaration
of Conformity”
The technical specifications of the blast chiller are listed on the CE label placed on the rear side of the body
.
A
Kw
Kg
CL.
Matricola
Ser. Number
Modello
Model
Cod.Art
Code
Tensione
Tension
Assorbimento
Absorption
Gas
Gaz
IP20, CLASS 1
Model
Registration Number
Climate class
Electrical power
Quantity of coolant
Manufacturing Company
Code article
Operating voltage
Power consumption
Type of coolant
Degree of protection